ADJ-14
SECTION 3 ADJUSTMENTS
<LW375/LW335/LB425/LB385/LB355/LB305>
Software: Data backup package (EEPROM data transfer tool)
Preparation:
 1.  Download the corresponed package data from the service web side and extract them. Move the folder "DataBackup" to the   
     top directory of the C drive on your PC. There are files in the folder as shown below .
 
- Projector data Read Tool Ver2.4.exe  
Data read out software 
 
- Projector data Write Tool Ver2.4.exe  
Data write down software
 
- COMCTL32.OCX  
 
 
Windows OCX file
 
- MSCOMM32.OCX  
 
 
Windows OCX file
 
- setting.in  
 
 
Setting file
 2.  Connect the serial terminal of projector and PC with an  
 RS-232C cable.
* State of power: AC cord disconnected
1. Backup procedure
  1.  Double click the icon of software [Projector data Read   
     Tool Ver2.4.exe] in the folder of "DataBackup". The control 
     window will appear.
  2.  Input 9-digit number on the text box as the file name. 
     e.g. serial number. This file will be stored in "DataBackup" 
 folder.
  3. Connect the AC cord and turn the projector on.
  4.  Select the available COM port number and then press   
      the button to start reading-out the EEPROM data from    
  the projector and stored it in your PC.
  5.  After completing the reading out, "OK" will be appear on 
      the window.
 [Note]
      If "NG" appears, should delete a created file and then take   
     step 4 again. Do not overwrite the data into a created file.
The backup procedure is completed.
Quit the software and turn the projector off and disconnect 
the AC cord.
Communication cable (straight)
D-Sub 9p (Male)
D-Sub 9p (Female)
Projector Connection terminals
Computer
Computer
Projector Connection terminals
D-Sub 9p (Male)
Communication cable (straight)
D-Sub 9p (Female)
AB1234567
Data file name
AB1234567
STEP2
Adjusted data backup
Page of 70
Display

Click on the first or last page to see other PT-LW375 / PT-LW335 / PT-LB425 / PT-LB385 / PT-LB355 / PT-LB305 (serv.man3) service manuals if exist.