When non-standard signal of VIDEO/S-VIDEO is inputted (VCR, VHD, etc.), horizontal synchronization might be disordered
according to connected equipment. In this case, set HPLL to OFF.
     ·    
EMULATE
Switching the operation of RS-232C command to communicate with models other than LB80 series.
     − 
− 
− 
− 
DEFAULT: LB80 series standard, F100 series standard, D3500
     − 
− 
− 
− 
TYPE1: L730/L780/L735/LB/LC series
     − 
− 
− 
− 
TYPE2: L785
     − 
− 
− 
− 
OTHER: Models other than the above-mentioned (Consult your dealer or Authorized Service Center for details.)
     ·    
AUDIO IN STANDBY
Setting the audio output when STANDBY
     − 
− 
− 
− 
OFF: Does not output it.
     − 
− 
− 
− 
ON: Outputs it.
Note:
     − 
− 
− 
− 
When setting it to "ON", audio source of the input channel when the power supply is turned off (switched to STANDBY)
is outputted. Do with the remote control unit, control panel or RS-232C communication when you switch the channel.
The audio volume can be adjusted by the remote control unit or RS-232C communication.
     ·    
OVER SCAN
Setting the rate of over scanning
     − 
− 
− 
− 
1: Approx. 6%
     − 
− 
− 
− 
2: Approx. 4%
Note:
     − 
− 
− 
− 
Normally, set it to "1".
     ·    
LAST POWER MEMORY
     − 
− 
− 
− 
ON: Ordinary mode [If unplugging the power code during the projecting mode (lamp ON), the projector will start from the
projecting mode when the power code will be connected next time.]
     − 
− 
− 
− 
OFF: Always becomes STANDBY mode [Even if unplugging the power code during the projecting mode (lamp ON), the
projector will start from the standby mode when the power code will be connected next time.]
Note:
It is effective only when the setting of "DIRECT POWER ON" that is the submenu of "OPTION" menu is OFF.
     ·    
CLOSED CAPTION
     − 
− 
− 
− 
STANDARD: To set the normal mode
     − 
− 
− 
− 
SPECIAL: To set the special mode
(For DVD and/or VCR with time-based corrector, jitter of the character is improved.)
Note:
     − 
− 
− 
− 
Do not change the setting when it is possible to receive normally.
Normally, set it to "STANDARD".
     ·    
MENU LOCK
Switching ON/OFF "MENU LOCK" function
     − 
− 
− 
− 
OFF: Accessible to MENU
     − 
− 
− 
− 
ON: The access to MENU is restricted (The password is required).
     − 
− 
− 
− 
When MENU LOCK is set to "ON", the password input screen is displayed when it accesses the menu, and the
adjustment in the menu item is locked.
     ·    
MENU LOCK PASSW ORD
Setting the password into MENU LOCK
     − 
− 
− 
− 
The default password is "AAAA".
When you want to reset the password into the default password, do the following operation.
 1. Press on the remote control unit the AUTO SETUP button, or on the main unit the INPUT SELECT button and the
button at the same time for 2 seconds or more.
 2. Press
button for 2 seconds or more.
     ·    
ANGLE RESET
Resetting "Real-time Keystone" reference level