ADJ-6
SECTION 3 ADJUSTMENTS
< JX200F >
1. 3. Date and time setup
1. Select the [DATE AND TIME] of [SETUP] menu.
2. Set the time zone, date, and time of the built-in clock of the projector.
  • For further instructions, refer to the operating instructions.
1. 2. Model information setup
1. Enter the service mode, and select submenu [MODEL] of [EXTRA OPTION] menu.
2. Select the model and press the [ENTER] button.
3. The model information will be applied after the main power restart.
4. Confirm the model information in the sub menu [STATUS] of the menu [PROJECTOR SETUP].
1. 4. Wheel index, Driver current, White balance adjustment
1. 4. 1. Equipment to be used
1. Dark room : Because it adjust based on the measurement results of the luminometer, dark room is required.
2. Screens : Appros 40 inch diagonal size white mat type screen.
3. Luminometer : Konica-Minolta CL-500A.
4. Communication cable for CL-500A : 1 (USB cable)
5. PC : Automatically adjusted using the service tool.
6. LAN cable : Used to communicate between the projector and computer
7. Service Software : NTN91000 Tool (Service Tool.exe (v2.0.0.2 or later))
1. 4. 2. Preparation
1. Set the wide end of zoom lens.
2. Set the throw distance at 1.06m (approx 40inch).
3. Connect the projector to PC with LAN cable.
4. Connect the luminometer to PC with USB cable.
S
cre
en
LA
N
 c
able
PC
1.06 m
Luminometer
USB cable
Projector
Dark room
Page of 84