PT-EZ770Z, PT-EZ770ZL, PT-EZ770ZD, PT-EZ770ZLD, PT-EZ770T, PT-EZ770TL, PT-EW730Z, PT-EW730ZL, PT-EW730ZD, PT-EW730ZLD, PT-EW730T, PT-EW730TL, PT-EX800Z, PT-EX800ZL, PT-EX800ZD, PT-EX800ZLD, PT-EX800T, PT-EX800TL - Panasonic Projector Service Manual (repair manual). Page 26

Read Panasonic PT-EZ770Z / PT-EZ770ZL / PT-EZ770ZD / PT-EZ770ZLD / PT-EZ770T / PT-EZ770TL / PT-EW730Z / PT-EW730ZL / PT-EW730ZD / PT-EW730ZLD / PT-EW730T / PT-EW730TL / PT-EX800Z / PT-EX800ZL / PT-EX800ZD / PT-EX800ZLD / PT-EX800T / PT-EX800TL Service Manual online

INF-18
SECTION 1 SERVICE INFORMATION
9. Attention
-  If a command is transmitted after the lamp starts illuminating, there may be a delay in response or the command may not be 
executed. Try sending or receiving any command after 60 seconds.
-  When transmitting multiple commands, be sure to wait until 0.5 seconds has elapsed after receiving the response from the 
projector before sending the next command.
-  It might take time by the time the response returns because the command is processed in the projector.
  Set the time-out to 10 seconds or longer.
4. 2. Control through LAN terminal
Possible to control this projector by connecting PC to the LAN terminal on this projector.
Connection and command transmission changes depending on mode (admin password is set or not with web control).
Control according to the procedure in "4.2.2" on the protection mode (the password is set), and according to the procedure in 
"4.2.3" on the unprotected mode (the password is not set).
4. 2. 1. Connection example
 
Computer
Projector
LAN cable (straight)
LAN cable (straight)
Hub
Note: Lan cable and Hub are not standard accessories. 
When connected directly, cross type cable is recommended.
4. 2. 2. When Web control administrator rights password is set (Protect mode)
4. 2. 2. 1. Connecting
1.  Obtain the IP address and port number (Initial setting value = 1024) of the projector and request for a connection to the 
projector.
  You can obtain both the IP address and the port number from the menu screen of the projector.
 - IP address  : Obtain from the main menu → [NETWORK] → [NETWORK STATUS]
 - Port number  : Obtain from the main menu → [NETWORK] → [NETWORK CONTROL] → [COMMAND PORT]
2. Check the response from the projector
 - Response data
Data section
Blank
Mode
Blank
Random number section
Termination symbol
"NTCONTROL"
(ASCII string)
' '
0x20
'1'
0x31
' '
0x20
"zzzzzzz"
(ASCII code hexadecimal number)
(CR)
0x0d
9 byte
1 byte
1 byte
1 byte
8 byte
1 byte
Mode: 1 = Protect mode
3. Generate a 32-byte hash value from the following data using MD5 algorithm.
 "xxxxxx:yyyyy:zzzzzzz"
xxxxxx
Administrator rights user name for Web control (default user name is “admin1”)
yyyyy
Password of above administrator rights user (default password is “panasonic”)
zzzzzzz
8-byte random number obtained in Step 2)
 
: colon : Separator
Page of 127
Display

Click on the first or last page to see other PT-EZ770Z / PT-EZ770ZL / PT-EZ770ZD / PT-EZ770ZLD / PT-EZ770T / PT-EZ770TL / PT-EW730Z / PT-EW730ZL / PT-EW730ZD / PT-EW730ZLD / PT-EW730T / PT-EW730TL / PT-EX800Z / PT-EX800ZL / PT-EX800ZD / PT-EX800ZLD / PT-EX800T / PT-EX800TL service manuals if exist.