-8-
Circuit Protections
This projector provides 2 mechanical sensor switches, the one is for air filter unit switch (SW1891) and the other one
is for lamp cover switch(SW901).
is for lamp cover switch(SW901).
The projector is shut down and the < ON(G)/STANDBY(R)> indicator lights in red and other
indicators are blinking.
indicators are blinking.
The air filter unit switch (SW1891) detects whether the air filter unit is installed correctly. If the air filter unit switch is
not installed correctly, the projector cannot turn on. In this case, the <ON(G)/STANDBY(R)> indicator lights in red and
other indicators are blinking.
- Check that the lamp cover is installed securely.
not installed correctly, the projector cannot turn on. In this case, the <ON(G)/STANDBY(R)> indicator lights in red and
other indicators are blinking.
- Check that the lamp cover is installed securely.
The projector is shut down and the < ON(G)/STANDBY(R)> and <LAMP> indicators are
blinking.
blinking.
The lamp cover switch (SW901) detects whether the lamp cover is closed securely. If lamp cover is opened or not
closed completely, the drive signal to the lamp circuit is cut off. After opening the lamp cover for replacing the new
lamp assy, place the lamp cover correctly otherwise the projector cannot turn on.
- Check that the air filter unit is installed securely.
closed completely, the drive signal to the lamp circuit is cut off. After opening the lamp cover for replacing the new
lamp assy, place the lamp cover correctly otherwise the projector cannot turn on.
- Check that the air filter unit is installed securely.
Air filter unit switch
(SW1891)
(SW1891)
Lamp cover switch(SW901)
Air filter unit
Mechanical sensor switches
ON(G)/STANDBY(R)
indicator
LED indicators (front view)
LAMP indicator