Read Panasonic PT-EZ570U / PT-EZ570E / PT-EZ570UL / PT-EZ570EL (serv.man2) Service Manual online
-16-
Maintenance
The LAMP indicator will light yellow when the lamp runtime (Corresponding value) reaches 3,000 hours. This is to
indicate that lamp replacement is required. The lamp runtime is calculated by using the below expression.
Lamp runtime (Corresponding value) =
indicate that lamp replacement is required. The lamp runtime is calculated by using the below expression.
Lamp runtime (Corresponding value) =
T
normal +
T
eco x 0.75
T
normal
: used time in the Normal and Auto mode
T
eco
: used time in the Eco1 and Eco2 mode
You can check the lamp runtime following to the below procedure.
1
Press and hold the
button on the projector or the POWER ON button on the remote control for more than 20
seconds.
2
The projector used time and lamp runtime will be displayed on the screen briefly as follows.
Counter
Projector
Projector
500H
Lamp
Normal
Normal
200H
Eco
300H
Corresponding value 425H
lamp runtime
Projector used time
Cumulative lamp
operating time in
each mode.
operating time in
each mode.
How to check lamp runtime
Warning message on the non-standard lamp used
If the non-standard lamp is used, the warning and confirmation messages will appear on the screen every startup.
Some of the functions are limited when the non-standard lamp is used in spite of the warning.
Some of the functions are limited when the non-standard lamp is used in spite of the warning.
Since the lamp is not standard, projec-
tor failed to read lamp data.
Continue to use this lamp?
Yes
No