PT-DZ8700U, PT-DS8500U, PT-DW8300U, PT-DZ110XE, PT-DS100XE, PT-DW90XE (serv.man11) - Panasonic Projector Service Manual (repair manual). Page 4

Read Panasonic PT-DZ8700U / PT-DS8500U / PT-DW8300U / PT-DZ110XE / PT-DS100XE / PT-DW90XE (serv.man11) Service Manual online

  PT-DZ8700U / PT-DS8500U / PT-DW8300U / PT-DZ110XE / PT-DS100XE / PT-DW90XE   
  
 
1. Safety Precautions 
1.1. General Guidelines 
·  
For continued safety, no modification of any circuit must be 
attempted. 
·  Unplug the power cord from the power outlet before 
disassembling this projector. 
·  Use correctly the supplied power cord and must ground it. 
·  It is advisable to use an isolation transformer in the AC power 
line before the service. 
·  Be careful not to touch the rotation part (cooling fan, etc.) of 
this projector when you service with the upper case removed 
and the power supply turned ON. 
·  Observe the original lead dress during the service. If a short 
circuit is found, replace all the parts overheated or damaged 
by the short circuit. 
·  After the service, all the protective devices such as insulation 
barriers, insulation papers, shields, and isolation R-C 
combinations must be properly installed. 
·  After the service, check the leakage current to prevent the 
customer from getting an electric shock. 
 
1.2. Leakage Current Check 
1.  Prepare the measuring circuit as shown in Fig.1. 
Be sure to use a voltmeter having the performance described in 
Table 1. 
 
 
 
 
 
 
 
 
Fig. 1 
 
Table 1 
 
 
 
 
 
 
 
 
 
Fig. 2 
2.  Assemble the circuit as shown in Fig. 2. Plug the power 
cord in a power outlet. 
3.  Connect M1 to T1 according to Fig. 2 and measure the 
voltage. 
4.  Change the connection of M1 from T1 to T2 and measure 
the voltage again. 
5.  The voltmeter must read 0.375 V or lower in both of steps 3 
and 4. This means that the current must be 0.75mA or less. 
6.  If the reading is out of the above standard, the projector 
must be repaired and rechecked before returning to the 
customer because of a possibility of an electric shock. 
1.3. UV Precaution and UHM Lamp 
Precautions 
·  Be sure to unplug the power cord from the power outlet when 
replacing the lamp. 
·  Because the lamp reaches a very high temperature during its 
operation, wait until it cools completely when replacing the 
Lamp Unit. 
·  The lamp emits small amounts of UV-radiation, avoid 
direct-eye contact with the light. 
·  The lamp unit has high internal pressure. If improperly 
handled, explosion might result. 
·  Because the high pressure lamp involves a risk of failure, 
never touch the lamp wire lead during the service. 
 
 
 
 
Page of 78
Display

Click on the first or last page to see other PT-DZ8700U / PT-DS8500U / PT-DW8300U / PT-DZ110XE / PT-DS100XE / PT-DW90XE (serv.man11) service manuals if exist.