6. Troubleshooting
  6. 1. Shutdown system
When something wrong such as stop of fan happens, the projector has a function to be on standby immediately.
Value "**" is changed by "Lamp mode", or "Fan mode" and "Setting attitude"
Counter value is displayed in ○.
 STANDBY/ON LED
 blinks in red 4 times
Inter lock SW
 ⇒Open the rear cover more than 1
seconds.
Lamp usage hour is over the guideline.
(Convert at Lamp power [HIGH] mode)
 LAMP LED blinks once
Lamp memory (EEPROM)
communication:
 ⇒No response(ACK)
 LAMP LED lights
Intake air temperature sensor
 ⇒Under -20 degree C
Optical block temperature sensor
 ⇒Under -20 degree C
Exhaust temperature sensor
 ⇒More than ** degrees C
Lamp hours is over.
 ⇒2500 hours
  (Shuts down after 10 min.)
Each FAN sense signal
 ⇒Slower than 50% of target for
more than 5 sec.
 STANDBY/ON LED: Red
 TEMP LED: Lights
 STANDBY/ON LED
 blinks in red 3 times
 No flashing or blinking
Optical module temperature sensor
 ⇒More than ** degrees C
 TEMP LED Blinks 2
times
 (Warning: TEMP LED
lights)
Cooling liquid pump speed
 ⇒Slower than 1000rpm more than 5
sec.
Intake air temperature sensor
 ⇒More than 48 degree C
  (High altitude mode: more than 43
degree C)
Ballast block:
Thermal protector (SW9601)
 ⇒ Over 115±5 degrees C
(Returns with 80±15 degree C)
Monitor LED indication
Cooling liquid unit pump has problem
OSD warning
Exhausting temperature sensor
 ⇒Under -20 degree C
DMD drive circuit is faulty or
Signal processing unit PCB is faulty or
Connector connection is faulty
Color wheel rotation speed
 ⇒Over 202Hz or Under 70Hz
Rotation problem with color wheel
FPGA initialized or
Communication error or
Formatter initial error
Replace lamp   Power off (Standby)
after ○ min“
"TEMPERATURE WARNING "
Intake air temperature problem
 Filter clogging
 High temperature of environment
 Intake air window is closed.
Exhaust temperature error.
 Closed ventilator
 Deteriorating exhaust fan
 High altitude mode is not on
Optical module temperature is low.
Adjust the setting circumstances.
Lamp is not installed
Cable for lamp memory has bad contact or
connection.
"TEMPERATURE WARNING "
Power fuse
 ⇒15A  250V
Thermal fuse
 (Automatic restoration type)
 ⇒More than 152 degrees Celsius
Possible factor
Blown out of the fuse
( with some reason )
Bimetal is OFF (with some reason)
Setting environment confirmation is required.
Inductor clogging
Something wrong with Ballast block
Shutdown detection
Rear cover is not installed.
 TEMP LED Blinks 3 times
Fan rotation problem
Connection problem with Intake air temperature
sensor
Faulty temperature sensor
Connection problem with optical block temperature
sensor
Faulty temperature sensor
Connection problem with exhausting temperature
sensor
Faulty temperature sensor
 LAMP LED blinks 3 times
Lamp status
 ⇒Lamp is off during the status other
than normal one
Failed making lamp ON, lamp abnormal condition
Ballast block faulty
Hot restart
 FILTER LED blinks once
(RED)
Filter is not installed
 ⇒Filter detect (SW1501)
      Not detect more than 10 minutes
Optical module temperature sensor
 ⇒After lamp lighting, less than 5
degrees C for more than 5 minutes.
“REPLACE FILTER.
IN ○ MINUTES,POWER WILL TURN
OFF
AND GO INTO STANDBY MODE
AUTOMATICALLY”.
46 degrees C (high altitude 41
degrees C) "TEMPERATURE
WARNING"
44 degrees C (high altitude 39
  
 
Optical module error.
 Cooling liquid unit attachment error
 Clogged ventilator
 High altitude mode is not on
Filter is not installed