PT-DZ6710U, PT-DZ6710E, PT-DZ6700U, PT-DZ6700E, PT-DW6300US, PT-DW6300ES, PT-D6000US, PT-D6000ES, PT-DZ6710UL, PT-DZ6710EL, PT-DZ6700UL, PT-DZ6700EL, PT-DW6300ULS, PT-DW6300ELS, PT-D6000ULS, PT-D6000ELS, PT-D6000ELK, PT-D6000EK, PT-DW630 - Panasonic Projector Service Manual (repair manual). Page 18

Read Panasonic PT-DZ6710U / PT-DZ6710E / PT-DZ6700U / PT-DZ6700E / PT-DW6300US / PT-DW6300ES / PT-D6000US / PT-D6000ES / PT-DZ6710UL / PT-DZ6710EL / PT-DZ6700UL / PT-DZ6700EL / PT-DW6300ULS / PT-DW6300ELS / PT-D6000ULS / PT-D6000ELS / PT-D6000ELK / PT-D6000EK / PT-DW630 Service Manual online

 3. Generates a hash value (message digest) from "admin1:panasonic:1aa6c14e" by using the MD5.
"admin1" = Administrator authority user-name
"panasonic" = Password corresponding to "admin1"
Hash value = "01466bc27ed8c0b7e607471580c55953"
 4. Transmits the command.
Transmission data = "01466bc27ed8c0b7e607471580c5595300QPW" + (CR)
 5. Receives a response.
Reception data = "00000" + (CR)
 6. Disconnects the connection with the projector.
Example 2: Query FILTER INFORMATION - RUNTIME "QFI:0"
 1. Connects to the projector.
IP = 192.168.0.8, Port number = 1024
 2. Receives a response.
Response = "NTCONTROL 1 0bda3637" + (CR)
"0bda3637" = 8 bytes random characters
 3. Generates a hash value (message digest) from "admin1:panasonic:0bda3637" by using the MD5 .
"admin1" = Administrator authority user-name
"panasonic" = Password corresponding to "admin1"
Hash value = "a5bf5df3e35c4802a6cdf21880f69093"
 4. Transmits the command.
Transmission data = "a5bf5df3e35c4802a6cdf21880f6909300QFI:0" + (CR)
 5. Receives a response.
Reception data = "00 (SP) (SP) 142" + (CR)
 6. Disconnects the connection with the projector.
5.2.2. When WEB CONTROL Admin Password is not set (Unprotected Mode)
5.2.2.1. Connection
 1. Access IP address and the port number (default = 1024) of the projector, then connect to the projector with them.
IP address and the port number can be accessed from the menu of the projector.
     ·    
IP address: MAIN MENU
NETW ORK
NETW ORK STATUS
     ·    
Port number: MAIN MENU
NETW ORK
NETW ORK CONTROL
COMMAND PORT
 2. Receive a response message.
Response Message
Data section
Space
Mode
End character
"NTCONTROL"
(ASCII character string)
´ ´
0x20
´0´
0x30
(CR)
0x0d
9 bytes
1 byte
1 byte
1 byte
Mode: 0 = Unprotected mode
5.2.2.2. Method of Command Transmission
Transmits command by the following format.
Transmission Data
Header
Data section
End character
´0´
0x30
´0´
0x30
Control command
(ASCII character string)
(CR)
0x0d
1 byte
1 byte
Undefined length
1 byte
Reception Data
Header
Data section
End character
´0´
0x30
´0´
0x30
Control command
(ASCII character string)
(CR)
0x0d
1 byte
1 byte
Undefined length
1 byte
18
PT-DZ6710U / PT-DZ6710E / PT-DZ6700U / PT-DZ6700E / PT-DW6300US / PT-DW6300ES / PT-D6000US / PT-D6000ES
Page of 127
Display

Click on the first or last page to see other PT-DZ6710U / PT-DZ6710E / PT-DZ6700U / PT-DZ6700E / PT-DW6300US / PT-DW6300ES / PT-D6000US / PT-D6000ES / PT-DZ6710UL / PT-DZ6710EL / PT-DZ6700UL / PT-DZ6700EL / PT-DW6300ULS / PT-DW6300ELS / PT-D6000ULS / PT-D6000ELS / PT-D6000ELK / PT-D6000EK / PT-DW630 service manuals if exist.