PT-DZ16KU, PT-DZ16KE, PT-DS16KD (serv.man13) - Panasonic Projector Service Manual (repair manual). Page 26

Read Panasonic PT-DZ16KU / PT-DZ16KE / PT-DS16KD (serv.man13) Service Manual online

SECTION 1  SERVICE  INFORMATION
<PT-DZ16K>
5. Cautions for service
  5. 1. Before service operation
    5. 1. 1. Lamp
1. Contact the dealer to purchase a replacement lamp unit.
2. A Phillips screwdriver is necessary when replacing the lamp unit.
3. Since the luminous lamp is made of glass, it may burst if dropped or hit with a hard object. Please handle with care.
4. The lamp may be burst. Replace the lamp unit carefully so that the broken pieces of the lamp glass will not scatter. 
    When the projector is mounted on the ceiling, do not make the replacement directly under the lamp unit or put your
    face near it.
5. When disposing of used lamp units, contact your local authorities for correct methods.
    5. 1. 2. Air filter unit
1. Contact the dealer to purchase a replacement air filter unit.
2. A Phillips screwdriver is necessary when replacing the air filter unit.
3. Air filter replacement is recommended after cleaning the unit two times.
    The dust-proof properties may be reduced after each cleaning.
[Caution]   When used the "Smoke cut filter", please enter the password and change the filter type settings.
When use is finished, return the filter settings to "NORMAL".
* For more information, please refer to the operating instructions of the smoke cut filter.
    5. 1. 3. Lithium battery
1. The lithium battery is used for the internal clock in the A-P.C. board. So when it consumed it must be replaced.
2. After replacing the lithium battery, set the "Date and Time" on the sub-menu which in main menu "projector set up".
    5. 1. 4. About use by vertical upwards / downward settings
This unit, clasp attached conditions to lamp case according to  Installation mode is different from PT-DZ21K series. 
It is necessary at all times regardless of the installation mode.
・ Clasp mounting correspondence table of each installation mode
* It becomes the cause that it hastens the life of the lamp when use it as wrong setting.
Vertical down setting
Lamp case L / R
Lamp case R
[Note]   Factory default, since clasps are attached to two places of each lamp case, please do not remove.
Nonuse
Ceiling setting
Lamp case L / R
Nonuse
Vertical up setting
Lamp case L / R
Lamp case L
    Replacement lamp unit  ET-LAD510 (1bulb)/ ET-LAD510F (4 bulbs)
Lithium battery : CR2032
[Attention]  Please be sure to read the warnings and notices on the lamp that is described in the Operating Instructions.
                    "Read this first!",  "Precautions for use", "Maintenance/replacement"
            Model
Installation mode
PT-DZ16K
< Reference >
PT-DZ21K series
Floor setting
Lamp case L / R
Model Number
Service Password
Filter Type setting
Self-diagnosis display
Reference
ET-SFR510
1111
SPECIAL
U75
Option Accessory
TXFKN01VKR9
1016
SPECIAL2
U79
Service parts (High functionality type)
Note: Use only specified lamp units.
*Use only specified lithium battery
Air filter unit : ET-EMF510
INF - 18
Page of 110
Display