SECTION 3  ADJUSTMENTS
<PT-DZ16K>
  1. 5. Model Information Setup
1. Setting to service mode and select sub menu "MODEL"
    of main menu "EXTRA OPTION".
2. Select a model and push the “ENTER” button.
3. When to turn off the main power and turned on again, 
    the setting is complete.
  1. 6. Clog sensor calibration
1. Setting to Service mode and select sub menu "CLOG SENSOR CALIBRATION" of main menu "EXTRA OPTION".
2. Select the meters above the sea level of the work place and push the "ENTER" button.
* After completing the "EEPROM data transfer", Please carry out.
* This operation should be done with the main body is completely assembled and set on the floor and the adjuster
   legs are set in the main body.
* Please replace with a new air filter before starting calibration.
* Please calibration at a location where there are no heat apparatus and supply opening of the air-conditioner.
3. When [ OK ] is selected and ENTER button is pressed, the calibration is executed.
・ When the calibration is started, the screen becomes whole magenta.
・ While calibrating, all lamps will light (QUAD mode).
・ Do not shut down the power of projector during the calibration.
・ The progress is shown at the left top portion of the display with % unit.
4. When the magenta screen will disappear in approx 30 minutes and it returns to the normal screen, 
    the calibration is completed.
    Turn the POWER switch OFF and turn ON it again, then confirm whether to operate normally.
30 %
ADJ - 7