DLP Based Projector
ORDER NO. VED0706378C0
D10
2
PT-D5700U / PT-D5700E / PT-D5700UL / PT-D5700EL / PT-DW5100U / PT-DW5100E / PT-DW5100UL / PT-DW5100EL
1
Safety Precautions
4
1.1.
General Guidelines
4
1.2.
Leakage Current Check
4
1.3.
UV Precaution and UHM Lamp Precautions
4
2
Specifications
5
3
Function for Safety
7
3.1.
Interlock Switch
7
4
Serviceman Mode
7
4.1.
Setting to Serviceman Mode
7
4.2.
Resetting to User Mode
8
4.3.
Functions in Serviceman Mode
9
5
Using the Serial Terminals
13
5.1.
Examples of Connection
13
5.2.
Pin Assignments and Signal Names
13
5.3.
Communication Conditions (Factory Setting)
13
5.4.
Procedure of Communication Condition Settings
14
5.5.
Control commands
14
5.6.
Cable specifications
15
6
Using a Wired Remote Control
16
6.1.
Connection Example
16
6.2.
Setting the Projector ID Number for Remote Control 16
7
Support for Service
18
7.1.
Supporting Methods
18
7.2.
Note for Replacement of P.C.Boards
18
7.3.
Replacement of the lithium battery on the A-P.C.Board 18
8
Cautions for Service
18
8.1.
Servicing Methods
18
8.2.
Light Source Lamp
18
9
Parts Location
19
9.1.
Electrical Parts Location
19
9.2.
Electromechanical Parts Location
19
10 Replacement of Lamp Unit
20
10.1. Before replacing the Lamp Unit
20
10.2. When to replace the Lamp Unit
20
10.3. Indication of Lamp Monitor
21
11 Disassembly Instructions
22
11.1. Flowchart for Disassembly
22
11.2. Removal of Upper Case
23
11.3. Removal of A-P.C.Board
23
11.4. Removal of J-P.C.Board
24
11.5. Removal of Power Module
24
11.6. Removal of R-P.C.Board
25
11.7. Removal of S-P.C.Board
25
11.8. Removal of Ballast-1 and Ballast-2 Modules
25
11.9. Removal of Lamp Unit
28
11.10. Removal of Projection Lens
28
11.11. Removal of Analysis Block
29
11.12. Removal of Synthesis Mirror
30
11.13. Removal of Color Wheel Block (Analysis Block)
31
11.14. Removal of Rod (complete)
32
11.15. Removal of Full Reflection Mirror (complete)
33
11.16. Removal of DMD Block (complete)
34
11.17. Removal of Mechanical Shutter Unit
35
12 Troubleshooting
36
13 Interconnection Block Diagram
47
13.1. Interconnection Block Diagram (1/2)
47
13.2. Interconnection Block Diagram (2/2)
48
14 Block Diagram
49
14.1. Power Supply
49
14.2. Signal Processing (1/2)
50
14.3. Signal Processing (2/2)
51
14.4. Fan/Motor Drive
52
15 Schematic Diagram
53
15.1. A-P.C.Board (1/9)
54
15.2. A-P.C.Board (2/9)
55
15.3. A-P.C.Board (3/9)
56
15.4. A-P.C.Board (4/9)
57
15.5. A-P.C.Board (5/9)
58
15.6. A-P.C.Board (6/9)
59
15.7. A-P.C.Board (7/9)
60
15.8. A-P.C.Board (8/9)
61
15.9. A-P.C.Board (9/9)
62
15.10. R/S-P.C.Board
63
15.11. J-P.C.Board
64
16 Circuit Boards
65
16.1. A-P.C.Board (Foil Side)
65
16.2. A-P.C.Board (Component Side)
66
16.3. J-P.C.Board
67
17 Terminal guide of ICs and transistors
69
18 Exploded Views
70
19 Replacement Parts List
74
CONTENTS
Page
Page
3
PT-D5700U / PT-D5700E / PT-D5700UL / PT-D5700EL / PT-DW5100U / PT-DW5100E / PT-DW5100UL / PT-DW5100EL
1 Safety Precautions
1.1. General Guidelines
·
For continued safety, no modification of any circuit must be
attempted.
attempted.
·
Unplug the power cord from the power outlet before
disassembling this projector.
disassembling this projector.
·
Use correctly the supplied power cord and must ground it.
·
It is advisable to use an isolation transformer in the AC
power line before the service.
power line before the service.
·
Be careful not to touch the rotation part (cooling fan, etc.) of
this projector when you service with the upper case
removed and the power supply turned ON.
this projector when you service with the upper case
removed and the power supply turned ON.
·
Observe the original lead dress during the service. If a short
circuit is found, replace all the parts overheated or
damaged by the short circuit.
circuit is found, replace all the parts overheated or
damaged by the short circuit.
·
After the service, all the protective devices such as
insulation barriers, insulation papers, shields, and isolation
R-C combinations must be properly installed.
insulation barriers, insulation papers, shields, and isolation
R-C combinations must be properly installed.
·
After the service, check the leakage current to prevent the
customer from getting an electric shock.
customer from getting an electric shock.
1.2. Leakage Current Check
1. Prepare the measuring circuit as shown in Fig.1.
Be sure to use a voltmeter having the performance
described in Table 1.
described in Table 1.
Fig. 1
Table 1
Fig. 2
2. Assemble the circuit as shown in Fig. 2. Plug the power
cord in a power outlet.
3. Connect M1 to T1 according to Fig. 2 and measure the
voltage.
4. Change the connection of M1 from T1 to T2 and measure
the voltage again.
5. The voltmeter must read 0.375 V or lower in both of steps
3 and 4. This means that the current must be 0.75 mA or
less.
less.
6. If the reading is out of the above standard, the projector
must be repaired and rechecked before returning to the
customer because of a possibility of an electric shock.
customer because of a possibility of an electric shock.
1.3. UV Precaution and UHM Lamp
Precautions
·
Be sure to unplug the power cord from the power outlet
when replacing the lamp.
when replacing the lamp.
·
Because the lamp reaches a very high temperature during
its operation, wait until it cools completely when replacing
the Lamp Unit.
its operation, wait until it cools completely when replacing
the Lamp Unit.
·
The lamp emits small amounts of UV-radiation, avoid direct-
eye contact with the light.
eye contact with the light.
·
The lamp unit has high internal pressure. If improperly
handled, explosion might result.
handled, explosion might result.
4
PT-D5700U / PT-D5700E / PT-D5700UL / PT-D5700EL / PT-DW5100U / PT-DW5100E / PT-DW5100UL / PT-DW5100EL