11.9. Removal of Ballast-1 and Ballast-2 Modules
(1)
Remove the upper case according to the section 11.2. "Removal
of Upper Case".
(2)
Unscrew the 2 screws and remove the CW fan fixing metal and
the cooling plate.
(3)
Unscrew the 3 screws and release the grounding terminals.
(4)
Unscrew the 2 screws and release the lamp unit terminals.
(5)
Loosen the 2 screws until they idle and open the exhaust fan unit
2.
(6)
Loosen the 2 screws fixing the lamp unit until they idle and
remove the lamp unit 2.