ET-YFB100G - Panasonic Projector Service Manual (repair manual). Page 4

Read Panasonic ET-YFB100G Service Manual online

1. Safety Precautions
  1.1. General Guidelines
  1.2. Leakage Current Check
1. Prepare the measuring circuit as shown in Fig.1.
    Be sure to use a voltmeter having the performance described in Table 1.
2. Assemble the circuit as shown in Fig.2. Plug the power cord in a power outlet.
3. Connect M1 to T1 according to Fig.2 and measure the voltage.
4. Change the connection of M1 from T1 to T2 and measure the voltage again.
5. The voltmeter must read 0.375 V or lower in both of steps 3 and 4.  This means that the current must be 0.75mA or less.
6. If the reading is out of the above standard, the interface box must be repaired and rechecked before returning to the
    customer because of a possibility of an electric shock.
- For continued safety, no modification of any circuit must be attempted.
- Unplug the power cord from the power outlet before disassembling this interface box.
- Use correctly the supplied power cord and must ground it.
- It is advisable to use an isolation transformer in the AC power line before the service.
- Be careful not to touch the power supply part of this interface box when you service with the upper case removed and
   the power supply turned ON.
- Observe the original lead dress during the service. If a short circuit is found, replace all the parts overheated
  or damaged by the short circuit.
- After the service, all the protective devices such as insulation barriers, insulation papers, shields, and isolation
  R-C combinations must be properly installed.
- After the service, check the leakage current to prevent the customer from getting an electric shock.
Fig.1
Fig.2
Table. 2
4
Page of 32
Display

Click on the first or last page to see other ET-YFB100G service manuals if exist.