Read Panasonic KX-PX1CX Service Manual online
28
KX-PX1CX
39
P40/ (78KIRQ0#)
General port
L
Interruption request 0 (to the Print CPU)
O
W
40
*RESET
Reset input
L
ICE_RESET
Reset input signal from the MAIN microcom-
puter
Reset input signal from the MAIN microcom-
puter
I
41
P124/(SYS_ERR) General port
L
SYS_ERR
When control of the ERROR_LED is disabled
due to a problem with the MAIN microcom-
puter, the lighting control of ERROR_LED is
performed by the SUB microcomputer
When control of the ERROR_LED is disabled
due to a problem with the MAIN microcom-
puter, the lighting control of ERROR_LED is
performed by the SUB microcomputer
O
R
42
P123(iPOWER-
OFF)
OFF)
General port
H
POWER OFF request “H”: Enable (a request is
made)/ ”L” : Disable
Output a power off request to the CPU for the
display control system of PX10
made)/ ”L” : Disable
Output a power off request to the CPU for the
display control system of PX10
O
R
43
FLMD0
Programming mode
H
Flash write mode inside 78K (during writing:
High)
High)
I
44
P122/X2
General port/oscillation
-
Clock oscillator (10MHz)(10MHz)
O
45
P121/X1
General port/oscillation
-
Clock oscillator (10MHz)(10MHz)
I
46
REGC
Built-in regulator
Condenser terminal for the inside power supply
regulator
regulator
-
47
VSS
GND
GND
-
48
VDD
Power supply
3.3v power supply
-
Pin
Signal Name
Standard function
Act.
Purpose
I/O
R/W
Click on the first or last page to see other KX-PX1CX service manuals if exist.