TX-PR54Z11, TX-PR54Z1M, TU-Z100R, SP-R54Z1 - Panasonic Plasma Service Manual (repair manual). Page 18

Read Panasonic TX-PR54Z11 / TX-PR54Z1M / TU-Z100R / SP-R54Z1 Service Manual online

18
5.2.2.
Service tool mode
5.2.2.1.
How to access
1. Select [SRV-TOOL] in Service Mode.
2. Press [OK] button on the remote control.
5.2.2.2.
Display of SOS History
SOS History (Number of LED blinking) indication.
From left side; Last SOS, before Last, three occurrence before, 2nd occurrence after shipment, 1st occurrence after shipment.
This indication will be cleared by [Self-check indication and forced to factory shipment setting].
5.2.2.3.
POWER ON Time, On/Off
Note : To display Time, On/Off menu, highlight position, then press MUTE for 3sec. 
Time : Cumulative power on time, indicated hour : minute by decimal
On/Off : Number of On/Off switching by decimal
Note : This indication will not be cleared by either of the self-checks or any other command.
5.2.2.4.
Exit
1. Disconnect the AC cord from wall outlet or switch off the power with [ Power ] button on the Display unit.
Page of 127