TH-65PF12EK - Panasonic Plasma Service Manual (repair manual). Page 20

Read Panasonic TH-65PF12EK Service Manual online

20
TH-65PF12EK
8 Service Fixture & Tools
8.1.
SC jig
Purpose:
To find the failure board (SC or SU/SD) when the power LED is blinking 7 times.
SC jig:
Jumper connector to connect to SC50 connector on SC board
Part number:
TZSC09187
How to use:
Caution: Remove SC jig from SC board after inspection.
1. Remove all connector between SC board and SU/SD board to isolate SC board from both SU and SD board electrically. 
Note: The board will be damaged if all connector is not removed (for example; remove connector only for SU board 
and stay connecting with SD board. The board will be damaged.) 
2. Connect SC jig to connector SC51 at left bottom side of SC board.
3. Turn on the TV/Display Unit and confirm the power LED blinking.
LED blinking: Possible cause of failure is in SC board
No LED blinking (Lighting or no lighting): Possible cause of failure is in SU or SD board
4. After inspection, turn off the TV/Display Unit and wait a few minutes to discharge.
5. Remove SC jig from SC board.
Remark: This SC jig can be used for all 2009 Plasma TV and Plasma Display.
Page of 127
Display

Click on the first or last page to see other TH-65PF12EK service manuals if exist.