7.11. Remove the SS3-Board
1. Disconnect the connector (SS03) and disconnect the flex-
ible cable (SS57).
2. Remove the screws (
×2 
) and remove the SS3-Board. 
7.12. Remove the SS-Board
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (SS02 and SS03).
3. Disconnect the connectors (SS11, SS12, SS23 and
SS34).
4. Disconnect the flexible cables (SS54 and SS55).
5. Remove the molding prop (
×1 ).
6. Remove the screws (
×5 
) and remove the SS-Board.
7.13. Remove the Stand brackets
1. Remove the Plasma panel section from the servicing
stand and lay on a flat surface such as a table (covered)
with the Plasma panel surface facing downward.
2. Remove the Stand brackets (L, R) fastening screws (
×5
 each) and remove the Stand brackets (L, R).
7.14. Remove the C1-Board
1. Remove the tuner unit. (See section 7.4.)
2. Remove the Stand bracket R. (See section 7.13.)
3. Remove the flexible cables holder fastening screws (
×10
).
4. Disconnect the flexible cables (CB1, CB2, CB3, CB4 and
CB5).
5. Disconnect the flexible cables (C10 and C11).
6. Remove the screws (
×6 
) and remove the C1-Board.