TH-50PV8P, TH-50PX8B, TH-50PX8E - Panasonic Plasma Service Manual (repair manual). Page 23

Read Panasonic TH-50PV8P / TH-50PX8B / TH-50PX8E Service Manual online

23
Caution:
• Please confirm the installation place of BC hook (L, R)
Spacer and Spacer Ring when you exchange the Plasma
panel, and install BC hook (L, R) Spacer and Spacer Ring in
an original installation place after exchanging the Plasma
panel.
7.21. Remove the S-Board
1. Remove the Cabinet assy. (See section 7.20.)
2. Disconnect the connector (S1).
3. Remove the screws (
×2 
) and remove the S-Board
metal frame.
4. Remove the screws (
×2 
) and remove the S-Board.
7.22. Remove the K-Board
1. Remove the Cabinet assy. (See section 7.20.)
2. Remove the S-Board. (See section 7.21.)
3. Remove the screws (
×2 ).
4. Disconnect the connector (K1) and Remove the K-Board.
7.23. Remove the plasma panel (fin-
ished)
1. Place the new plasma panel (finished) on the flat surface
of the table (covered by a soft cloth), with the plasma
panel surface facing downward.
2. Attach the C1-Board, C2-Board and the C3-Board, con-
nect the flexible cables (
×11) from the plasma panel to the
C1-Board, C2-Board and the C3-Board, and fit the flexi-
ble cable holders.
3. Attach the Hooks (left, right) and fit the stand brackets (L,
R) to the new plasma panel.
4. Place the plasma panel section on the servicing stand.
5. Attach the cabinet assy and each P.C.Board and so on, to
the new plasma panel.
*When fitting the cabinet assy, be careful not to allow 
any debris, dust or handling residue to remain 
between the front glass and plasma panel.
Page of 120