1.13. Sustain Step 4
Fig. M
When sustain pulse is stopped, Ions and Electrons are
remained again as Wall voltage. However polarity of wall
voltage is reversed.
1.14. Sustain Step 5
Fig. N
Ions and Electrons which is generated by 2nd sustain
discharge are charged on the pixel wall(dielectric) around the
electrodes.
1.15. Repeat Step 1 to Step 5
Fig. O
To keep discharge continuously step 1 to 5 operation will be
repeated.
As the result sustain pulse is alternated. Therefore we call this
drive system AC Drive type.
If sustain operation is repeated longer, brightness level of the
pixel is increased. Therefore depend on sustain discharge time
brightness of pixel is controlled.
1.16. Sub-Field drive
Fig. P
Sub-Field drive is PDP unique system.
While one TV field period, 8 bits digital video signal component
is reproduced by 8 sub-fields operation.
Each Sub-Field´s address period are all same.(Consist of one
initialization and 768 scanning operation)
But Sustain period of each Sub-Field are different.1st Sub-
Field(SF) reproduce only 1 step brightness.
2nd SF reproduce 2 steps brightness.
Each sub-field´s sustain period are increased gradually.
However total 256 brightness difference can be reproduced on
the screen.