Read Panasonic TH-50PH10BK / TH-50PH10BS / TH-50PH10EK / TH-50PH10ES (serv.man2) Service Manual online
6 Disassembly
· To disassemble P.C.B., wait for 1 minute after power was
off for discharge from electrolysis capacitors.
· and
marks indicate screw positions.
6.1. Removal of the Back Cover
1. Remove screws (×7
, ×4
, ×10
, x12
) and then
remove the Back Cover.
6.2. Removal the of HU-Board
1. Remove 4 screws (A) and then remove the HU Terminal
Block.
2. Remove 4 screws (B).
3. Remove 3 screws (C) and then remove HU-Board.
6.3. Removal of the Slot Block
1. Remove the HU Terminal Block.
(Reference to Removal of the HU-Board)
2. Remove the flexible cable from the connector (DS1).
3. Disconnect the connectors (DS2, DS4, DS6, DS7, DS8,
DS15).
4. Remove 4 screws and then remove the Slot-Block.
6.4. Removal of the DS-Board
1. Remove the HU Terminal Block.
(Reference to Removal of the HU- Board)
2. Remove the Slot Block.
(Reference to Removal of the Slot Block)
3. The Slot Block is turned inside out.
4. Remove 6 screws and then remove the Slot cover.
5. Remove 6 screws.
6. Remove the DS-Board.
9
TH-50PH10BK / TH-50PH10BS / TH-50PH10EK / TH-50PH10ES