TH-42PD12E - Panasonic Plasma Service Manual (repair manual). Page 10

Read Panasonic TH-42PD12E Service Manual online

10
TH-42PD12E
GPH12D chassis series have special function and operation setting facility called Option Menu. This Option Menu is use-
ful for special function required customers. This should be set at the installation stage.
Note:
When both main unit buttons and remote control are disabled due to the “Button lock”, “Remocon User level” or “Remote ID”
adjustments, set all the values “Off” so that all the buttons are enabled again.
Press the “Volume down” button on main unit together with “R” button on the remote control and hold for more than 5 seconds.
The “SHIPPING“ menu is displayed and the lock is released when it disappears.
Option Menu for GPH12D series
Option menus
default setting
Contents
Onscreen display
On
Enable/Disable to display input mode indication after power on and no signal 
indication.
Initial INPUT
Off
Sets the initial input mode when the power is turned on. Allow input mode selec-
tion while power is on.
Initial VOL level
Off
Sets the initial volume level when the power is turned on. Allow Volume control 
while power is on.
Maximum VOL Level
Off
Sets the maximum volume to desired level. Volume cannot exceed this level.
INPUT lock
Off
Fixes the input mode to AV, Component/RGB or PC. Can not change input 
mode by input selection key.
Button lock
Off
Enable/Disable bottom operation buttons (Input, Menu, Enter and/or volume up/
down)
Remocon User Level
Off
Remote key invalidation.
Off: Valid key is all key of remote.
User1: Valid key are only Stand-by (ON/OFF), Input, Direct input, Picture, Sur-
round, Sound mute On/Off, and volume adjustment.
User2: Valid key is only Stand-by (ON/OFF).
User3: All keys are null and void
Off-timer function
Enable
Off-timer operation Enable/Disable.
Initial Power Mode
Normal
Sets the power mode of the unit for when the power recovers from failure or 
after plugging off and in again.
ID select
0
Set ID number from 0 to 100.
Remote ID
Off
Remote ID function On/Off.
(While the Remote ID on, standard remote function can not control the unit.)
Serial ID
Off
Serial ID function On/Off
Display size
Off
Display size function On/Off
Studio W/B
Off
Studio W/B function On/Off
Studio Gain
Off
Studio Gain function On/Off
Power On Screen Delay
Off
You can set the power-on delay time of the displays to reduce the power load, 
when you press 
 to turn on the multiple displays that are set together, for 
example, on MULTI DISPLAY system.
Set each display’s setting individually.
All Aspect
Default
Aspect mode: default/All aspect mode.
Auto Setup
Manual
Sets the operational mode of the automatic position adjustment in the POS./
SIZE memu. 
Rotate
Off
Rotate function On/Off
Page of 127
Display

Click on the first or last page to see other TH-42PD12E service manuals if exist.