CF-18NHHZXBM - Panasonic PC Service Manual (repair manual). Page 10

Read Panasonic CF-18NHHZXBM Service Manual online

3-1 
3. List
 
of
 
Error
 
Codes
 
<Only when the port replicator is connected>
 
 
The following is a list of the messages that BIOS can display. Most of them occur during  POST. 
Some of them display information about a hardware device, e.g., the amount of memory 
installed. Others may indicate a problem with a device, such as the way it has been configured. 
Following the list are explanations of the messages and remedies for reported problems. 
If your system displays one of except the messages marked below with an asterisk (*), write 
down the message and contact Panasonic Technical Support. If your system fails after you  make 
changes in the Setup menus, reset the computer, enter Setup and install Setup defaults or correct 
the error. 
 
0200 Failure Fixed Disk 
Fixed disk in not working or not configured properly. Check to see if fixed disk is attached 
properly. Run Setup. Find out if the fixed-disk type is correctly identified. 
0210 Stuck key 
Stuck key on keyboard. 
0211 Keyboard error 
Keyboard not working. 
0212 Keyboard Controller Failed 
Keyboard controller failed test. May require replacing keyboard controller. 
0213 Keyboard locked - Unlock key switch 
Unlock the system to proceed. 
0230 System RAM Failed at offset: nnnn 
System RAM failed at offset nnnn of in the 64k block at which the error was detected. 
0231 Shadow RAM Failed at offset: nnnn 
Shadow RAM failed at offset nnnn of the 64k block at which the error was detected. 
0232 Extended RAM Failed at offset: nnnn 
Extended memory not working or not configured properly at offset nnnn
0250 System battery is dead - Replace and run SETUP 
The CMOS clock battery indicator shows the battery is dead. Replace the battery and run 
Setup  to  reconfigure the system. 
*0251 System CMOS checksum bad - Default configuration used 
System CMOS has been corrupted or modified incorrectly, perhaps by an application 
program  that changes data stored in CMOS. The BIOS installed Default SETUP Values.   
If you do not  want these values, enter Setup and enter your own values. If the error persists, 
check the system  battery or contact Panasonic Technical Support. 
0260 System timer error 
The timer test failed. Requires repair of system board. 
0270 Real time clock error 
Real-time clock fails BIOS test. May require board repair. 
*0280 Previous boot incomplete - Default configuration used 
Previous POST did not complete successfully. POST loads default values and offers to run 
Setup. If the failure was caused by incorrect values and they are not corrected, the next boot 
will likely fail. On systems with control of wait states, improper Setup settings can also 
terminate  POST and cause this error on the next boot. Run Setup and verify that the 
wait-state  configuration is correct. This error is cleared the next time the system is booted. 
0281 Memory Size found by POST differed from EISA CMOS 
Memory size found by POST differed from EISA CMOS. 
 
 