KX-WT115RU - Panasonic PBX Service Manual (repair manual). Page 10

Read Panasonic KX-WT115RU Service Manual online

10
KX-WT115RU
4.3.3.
Charge Circuit
Circuit Operation:
When charging the handset on the Charger Unit, the charge current is as follows;
DC+pin of J1(+) 
→ F1 → R1 → CHARGE+pad → CHARGE+(Handset) → Q4 → D7→ F1 → BATTERY+... Battery... 
BATTERY- 
→ R45 → GND → CHARGE-(Handset)→ CHARGE-pad → DC-pin of J1(-)
In this way, the BBIC on Handset detects the fact that the battery is charged.
The charge current is controlled by switching Q9 of Handset.
4.3.4.
Battery Low/Power Down Detector
Circuit Operation:
“Battery Low” and “Power Down” are detected by BBIC which check the voltage from battery.
The detected voltage is as follows;
• Battery Low
Battery voltage: V(Batt)   2.35 V ± 50 mV
The BBIC detects this level and "
" starts flashing.
• Power Down
Battery voltage: V(Batt)   2.0 V ± 50 mV
The BBIC detects this level and power down.
4.3.5.
Speakerphone
The hands-free loudspeaker at SP+ and SP- is used to generate the ring alarm.