Read Panasonic KX-VCA002X Service Manual online
7
KX-VCA002X
6 Troubleshooting Guide
Note
Please don't reuse the net.
Please change it for a new one if you remove it.
Please change it for a new one if you remove it.
Conditions
Check Item
Checking points & methods
Actions
LED illumination failure
LED(D401)
Visually check if the LED(D401) emits light in
orange when you turn on power to the KX-VC600/
VC300 connected.
(Please confirm it after connected to KX-VC600/
VC300.)
orange when you turn on power to the KX-VC600/
VC300 connected.
(Please confirm it after connected to KX-VC600/
VC300.)
Replace D401.
Mute SW failure
Switch (SW401)
Check the voltage of SW401 when the Mute SW
is pressed and not pressed.
Monitor SW401 side of R421 with a tester.
(Please confirm it after connected to KX-VC600/
VC300.)
is pressed and not pressed.
Monitor SW401 side of R421 with a tester.
(Please confirm it after connected to KX-VC600/
VC300.)
When the button is pressed
and R421 >=0.5 V, replace
SW401.
and R421 >=0.5 V, replace
SW401.
When the button is not pressed
and 2.4V >=R421, replace
SW401.
and 2.4V >=R421, replace
SW401.
Connector failure
CN403
Check conductivity visually and with a tester.
Replace CN403.
Audio does not pass through.
Replace to PNLPVCA0021Z.
Damages to nets, cabinets,
cables
cables
Check visually.
Replace nets, cabinets, and
cables.
cables.