KX-UDT111RU (serv.man3) - Panasonic PBX Service Manual (repair manual). Page 37

Read Panasonic KX-UDT111RU (serv.man3) Service Manual online

37
KX-UDT111RU
11.1.2.2. How to execute Test command
1. Execute “Flash Program.exe”.
2. Select “Test command” sheet.
3. Enter command in command columu.
4. Click “Send”.
11.1.2.3. Commands
See the table below for frequently used commands.
Command name
Function
Example
EPR
Read the data of EEPROM
Type “EPR 00 00 FF”, and the data from address “00 00” to “FE” is read out.
IDR
Read ID (RFPI)
Type “IDR”, and the registered ID is read out.
IDW
Write ID (RFPI)
Type “IDW 00 18 E0 0E 98”, and the ID “0018 E0 0E 98” is written.
VER
Read software version
Type “VER”.
EPW
Write the data of EEPROM
Type “EPW 01 23 01 45”. “01 23” is address, “01” is length and “45” is data to be written.
SFR
Clock adjustment value
Type "SDR xx xx". xx xx starts at 0100. Depending on the value of the frequency of test
point SKM, it changes forward and backward. It ends when it is in range of 13.824MHz ±
7Hz.
LED
LED control
Type"LED F". All of the FEF LED, the Yellow green LED the LCD Back Light and the Key
Back Light light up.
Type "LED 1". The RED LED lights up.
Type "LED 2". The Yellow green LED lights up.
VIB
VIB Motor control
Type "VIV 1". The VIB operates.
Page of 64