3 Specifications
3.1.
General Description
3.2.
Characteristics
Control Bus
Original bus (16-bit, 24 MHz) 
Switching
Space Division CMOS Cross point Switch 
Power Input
100 V AC to 240 V AC, 0.8A to 0.4A, 50 Hz/60Hz 
External Battery
+24 V DC (+12 V DC x 2) 
Maximum Power Failure Tolerance
300 ms (without using backup batteries)
Memory Backup Duration
7 years
Dialling
Outside (CO) Line
Pulse (10 pps, 20 pps) or Tone (DTMF)
Extension
Pulse (10 pps, 20 pps) or Tone (DTMF)
Intercom Path
3
Mode Conversion
Pulse-DTMF
Ring Frequency 
20 Hz/25 Hz (selectable)
Operating Environment 
Temperature
°C to 40 °C
Humidity 
10% to 90% (non-condensing)
Conference Call Outside (CO) Line
2
Music on Hold (MOH)
1 port
Selectable MOH: Internal/External/Tone
Paging
Internal
1
Extension
1 port
Serial Interface Port
RS-232C 
1
USB 1.1
1
Extension Connection Cable
SLT
1 pair wire (T, R)
PT
2-pair wire (T, R, H, L)
DSS Console
1-pair wire (H, L)
Dimension
249 mm (W) x 316 mm (H) x 73 mm (D)
Weight (when fully expanded)
Approx. 1.8 kg
Terminal Equipment Loop Limit
PT
40 
SLT
600 
Ω including set
Doorphone
20 
Minimum Leakage Resistance
15000 
Ω minimum
Maximum Number of Extension
Instruments per Line
1 PT or SLT in standard connection
1 PT and 1 SLT in parallel connection
Ring Voltage
65 Vrms at 20 Hz/25 Hz depending on the ringing load
Outside (CO) Line Loop Limit
1600 
Ω maximum
Hook switch Flash/Recall Timing Range
24 ms-2032 ms
Door Opener Current Limit
30 V DC/30 V AC, 3 A maximum
Paging Terminal Impedance
600 
MOH Terminal Impedance
10000 
Ω 
Page of 115