KX-TDA6178X, KX-TDA6178XJ - Panasonic PBX Service Manual (repair manual). Page 7

Read Panasonic KX-TDA6178X / KX-TDA6178XJ Service Manual online

7
     KX-TDA6178X/KX-TDA6178XJ
• LED Operation status indicating LED (Two colors)
OFF: Fault
Red ON: Fault (RESET included)
Green ON: Normal (Line not in use)
Green Flash (60/minute): Normal (Line in use)
Orange: OUS (Because OUS needs to be controlled by MPR, reset terminal and port control terminal are Red Blinking: OUS to
generate OUS)
• Instantaneous power interruption operation
When instantaneous power interruption is 300msec or less, reset operation is not carried out because the voltage is retained by
the capacitor in the power supply.
After HALT from MPR is detected at the DC power down port, CPU goes into the sleep mode by executing the instruction of
SLEEP.
At the sleep mode, the CPU/Clock enters the halt state while the contents of the register, the internal RAM, and the I/O port are
maintained.
When the instantaneous power interruption is released, HALT is negated, and CPU is recovered to the normal mode by the
detection of IRQ0=L