KX-TDA6111XJ, KX-TDA6111X - Panasonic PBX Service Manual (repair manual). Page 14

Read Panasonic KX-TDA6111XJ / KX-TDA6111X Service Manual online

Pin No.
Pin Name
I/O
DiscriptionPin Usage
17
VDD
+3.3 Volt Power Supply.
18
D4/AD4
I/O
Data Bus (bit4)
19
D5/AD5
I/O
Data Bus (bit5)
20
VSS
Ground
21
D6
I/O
Data Bus (bit6)
22
D7
I/O
Data Bus Åibit17)
23
D8
I/O
Data Bus Åibit18)
24
D9
I/O
Data Bus Åibit19)
25
VDD
+3.3 Volt Power Supply.
26
D10
I/O
Data Bus Åibit10)
27
D11
I/O
Data Bus Åibit11)
28
VSS
Ground
29
D12
I/O
Data Bus Åibit12)
30
D13
I/O
Data Bus Åibit13)
31
NC (Open)
No Connection.
32
VSS
Ground
33
VDD
+3.3 Volt Power Supply.
34
D14
I/O
Data Bus Åibit14)
35
D15
I/O
Data Bus Åibit15)
36
NC (Open)
No Connection.
37
NC (Open)
No Connection.
38
nRESET
I
Reset Input (low active)
39
VSS
Ground
40
nINTR
O
Interrupt Output
41
TXEN
O
Port1 Transmission Enable Output
42
TXD
O
Transmission Data Output (Port 1 2 common)
43
TXEN2
O
Port2 Transmission Enable Output
44
VSS
Ground
45
TXENPOL
I
TXEN TXEN2 Polarity Specification
46
RXIN
I
Port1 Reception Data Input
47
ET1
I
ARCNET Enhancing Timer Setting 1
48
RXIN2
I
Port2 Reception Data Input
49
VDD
+3.3 Volt Power Supply.
50
nDIAG
Diagnostic Mode Selection
51
nSTALONE =H
I
Standalone Mode Selection
52
NSTPRE0
I
NST Resolution Setting
53
NSTPRE1
I
NST Resolution Setting
54
NSTPRE2
I
NST Resolution Setting
55
NC (Open)
No Connection.
56
PS0
I
Page Size Specification (0 fixed)
57
PS1
I
Page Size Specification (0 fixed)
58
NC (Open)
No Connection.
59
NID0
I
Local Node Number Setting (1 fixed)
60
NID1
I
Local Node Number Setting (0 fixed)
61
NID2
I
Local Node Number Setting (0 fixed)
62
NID3
I
Local Node Number Setting (0 fixed)
63
NID4
I
Local Node Number Setting (0 fixed)
64
VSS
Ground
65
VDD
+3.3 Volt Power Supply.
66
NC (Open)
No Connection.
67
MAXID0
I
MAX Identification Number Setting (0 fixed)
68
MAXID1
I
MAX Identification Number Setting (1 fixed)
69
MAXID2
I
MAX Identification Number Setting (0 fixed)
70
MAXID3
I
MAX Identification Number Setting (0 fixed)
71
MAXID4
I
MAX Identification Number Setting (0 fixed)
72
NC (Open)
No Connection.
73
CKP0
I
Transmission Rate Setting (0 fixed)
74
CKP1
I
Transmission Rate Setting (0 fixed)
75
CKP2
I
Transmission Rate Setting (0 fixed)
76
VSS
Ground
77
NC (Open)
No Connection.
78
NC (Open)
No Connection.
79
NC (Open)
No Connection.
80
MCKIN
I
External Master Clock Input
81
VDD
+3.3 Volt Power Supply.
82
X1
I
Crystal Oscillator
83
X2
O
Crystal Oscillator
14
KX-TDA6111XJ / KX-TDA6111X
Page of 24
Display