KX-TDA100DUP - Panasonic PBX Service Manual (repair manual). Page 8

Read Panasonic KX-TDA100DUP Service Manual online

8
KX-TDA100DUP
3.3.2.
Maximum Terminal Equipment
The following number of items of terminal equipment can be supported by the PBX. For how to count the total number of items
of equipment to be connected, refer to "Power Supply Unit Capacity".
*1 When the PBX is equipped with 104 DPTs (Digital XDP), 48 IP-PTs, and 24 SLTs.
3.3.3.
Power Supply Unit Selection
Calculate the load figure from the type and number of items of equipment to be connected.
Load Figure Calculation
*1 Only the extension cards that can support SLTs count for the load figures.
Maximum Load Figure
The pre-installed power supply unit (PSU) supports the following load figures.
In addition to any combination of equipment totalling a load figure of up to 104, one additional MCSLC16 card (load figure: 16)
or one MCSLC24 card (load figure: 24) may also be added, for a total load figure of up to 128.
Calculation Example
Terminal Equipment Type
Maximum Number
Telephone
176*1
SLT
128
KX-DT300/KX-T7600 series DPT
104
IP-PT
112
DSS console
8
CS
26
High-density CS
13
PS
128
Voice Processing System (VPS)
2
Doorphone
16
Door Opener
16
External Sensor
16
External Relay
16
Equipment Type
Load Figure
PT
KX-DT300 series DPT/KX-DT300 series DSS
console/KX-T7600 series DPT/KX-T7600 series
DSS console
1
IP-PT
0
Trunk Card
DID8
16
E&M8
8
Others
0
Extension Card*1
MCSLC16
16
MCSLC24
24
CS (1 unit)
4
PT-interface CS (1 unit)
4
PT-interface CS (High-density) (1 unit)
8
ISDN Extension
2
VPS (1 port)
1
System Equipment
Maximum Load Figures
Any Equipment
104
Any EquipmentAdditional Load Capacity for a MCSLC16/
MCSLC24 Card
24
Total
128
Equipment Type
Load Figure
KX-DT300/KX-T7600 series DPT
4 units
4
MCSLC24
4 cards
96
VPS
8 ports
8
Total
108
Page of 127
Display

Click on the first or last page to see other KX-TDA100DUP service manuals if exist.