KX-TDA100DUP - Panasonic PBX Service Manual (repair manual). Page 6

Read Panasonic KX-TDA100DUP Service Manual online

6
KX-TDA100DUP
3 Specifications
3.1.
General Description
3.2.
Characterstics
Control Bus
Original bus (16 bit, 8 MHz,10 megabytes per second)
Communication Bus
H.100 bus conformity (1024 time slot)
Switching
Non-blocking
Power Input
100 V AC to 130 V AC;2.8 A/200 V AC to 240 V AC;1.7 A ;50 Hz/60 Hz
External Battery
+36 V DC (+12 V DC x 3, recommended maximum capacity is 28 Ah)
Maximum Power Failure Tolerance
300 ms (without using backup batteries)
Memory Backup Duration
 7 years
Dialling  
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Extension 
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Mode Conversion 
DP-DTMF, DTMF-DP
Ring Frequency 
20 Hz/25 Hz (selectable)
Trunk Loop Limit 
1600 
Ω maximum
Operating
Environment
Temperature
 0 
°C to 40 °C
Humidity
10%to 90% (non condensing)
Conference Call Trunk 
From 10 x 3-party conference call to 4 x 8-party conference call
Music on Hold (MOH)
2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Paging
Internal 
Level Control: -15 dB to +6 dB in 3 dB steps
External 
2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
Serial Interface Port
RS-232C 
1 (max 115.2 kbps)
USB
1
Extension Connection Cable
SLT 
1 pair wire (T, R)
DPT 
1-pair wire (D1, D2) or
2-pair wire (T, R, D1, D2)
PT-interfiace CS
1-pair wire (D1, D2) 
PT-interfiace CS (High-density)
4-pair wire (D1, D2)
DSS Consoles and Add-on Key Module
1-pair wire (D1, D2)
Dimension
334 mm (W) x 390 mm (H) x 270 mm (D)
Weight (when fully mounted)
Under 12 kg 
Terminal Equipment Loop Limit
• PT: KX-DT300/KX-T7600series DPT : 90 
• SLT: 600 
Ω including set
• Doorphone: 20 
• CS: 130 
Ω ; PT-interface CS : 65 Ω
Minimum Leakage Resistance
15 000 
Ω maximum
Maximum Number of Extension
Instruments per Line
1 for PT or SLT
2 by Parallel or eXtra Device Port connection of 2 DPTs
Ring Voltage
65 Vrms at 20 Hz/25 Hz depending on the Ringing Load
Trunk Loop Limit
1600 
Ω maximum
Hookswitch Flash/Recall Timing Range
24 ms to 2032 ms
BRI Cards Internal ISDN Mode
Supply Voltage: 40 V
Power Supply (BRI4) : 4.5 W per 1 line, 9 W per 4 lines
Power Supply (BRI8) : 4.5 W per 1 line, 9 W per 8 lines
Power Supply Method: Phantom Power Supply
Door Opener Current Limit
24 V DC/30 V AC, 1 A maximum
External Relay Current Limit
24 V DC/30 V AC, 1 A maximum
External Sensor Current Limit
Power to the external sensor is provided from the EIO4 card and must be grounded through
the EIO4 card. For the connection diagram, refer to "EIO4 Card (KX-TDA0164)". The PBX
detects input from the sensor when the signal is under 100 
Ω.
Paging Terminal Impedance
600 
MOH (Music on Hold) Terminal Impedance
10 000 
Page of 127
Display

Click on the first or last page to see other KX-TDA100DUP service manuals if exist.