KX-TDA100DUP (serv.man3) - Panasonic PBX Service Manual Supplement (repair manual). Page 4

Read Panasonic KX-TDA100DUP (serv.man3) Service Manual Supplement online

4
KX-TDA100DUP
1.4.
Technical Descriptions
Change from the Original Service Manual Section 17.3.
1.4.1.
Block Diagram
MCSLC24 BLOCK DIAGRAM
PLD 
TACKER/
SAMSON
Backboard
BB Connector
OSC16.3 8
4 M
OSC 
12.288M 
EC-Bus
CT-Bus 
15V 
Card_ID 
FLASH 
(512KB) 
SRAM 
(128KB) 
PCM-HW 
Serge
PFT 
Jack
T/R 
PFT            
Relay 
T/R 
SLIC/CODEC  
2ch 
Port1 
SCI(7pin) 
DC/DC 
3.3V 
FPGA_INT 
BELL_SYNC 
nHALT 
nIRQ1 
BELL_SYNC 
FPGA_INT 
Diag T/R 
nHALT 
40V 
Si32261
Diag 
Diag T/R 
nCS0
nCS1  
nCS2
nCS3 
nCS[3: 0] 
nIRQ1 
CPU 
nIRQ0 
nIRQ1 
nIRQ3 
Port4 
Port3 
Port2 
Port6 
Port5 
PFT      
 
Relay 
Port7
8
Port 23 24 
Port 21 22 
Port 19 20 
Port 17 18 
Port 15 16 
Port 13 14 
Port 11 12 
Port 9
10 
Si32261
Si32261
SPI 
C_CS[0:11]
C_INT[0:11]
nIRQ2 
Local 
Control 
Bus 
C_CS[0]  
C_CS[1]  
C_CS[2]  
C _INT[0]
C_INT[1]  
C_INT[2]  
C_INT[3]  
C_CS[3]  
PCM_HW 
SPI 
C_INT[4]  
C_CS[4]  
PCM_HW 
SPI 
C_INT[5]  
C_CS[5]  
PCM_HW 
SPI 
C_INT[6]  
C_CS[6]  
PCM_HW 
SPI 
C_INT[7]  
C_CS[7]  
PCM_HW 
SPI 
C_INT[8]  
C_CS[8]  
PCM_HW 
SPI 
C_INT[9]  
C_CS[9]  
PCM_HW 
SPI 
C_INT[10]  
C_CS[10]  
PCM_HW 
SPI 
C_INT[11]  
C_CS[11]  
PCM_HW 
SPI 
Port8
Port7
Port10
Port9 
Port12 
Port11 
Port14 
Port13 
Port16 
Port15 
Port18 
Port17 
Port20 
Port19 
Port22 
Port21 
Port24 
Port23 
Backboard
Con.
OSC32M 
Program
connector
Note1.Group of Signal lines
Local Control
 Bus
:
 connect to PLD
ADR[4:0],DATA[15:0], nWE , nR D ,nWAIT , CKIO
PCM - HW :
HWCLK
 ,HWFH
 ,DHW
 ,UHW
SPI :
SCLK
 ,DOUT
 ,DIN
LED x 2 
40V
Serge
DCDC
DCDC  
40V  
Relay
control
circuit
PR_SET
PF_RELAY
*1:These Blocks are not mounted on PCB.
PFT 
Jack
Serge
PFT  
Relay
PFT  
DCDC
Serge
DCDC
Relay
T/R
T/R
*1
Page of 44
Display

Click on the first or last page to see other KX-TDA100DUP (serv.man3) service manuals if exist.