Read Panasonic KX-TDA0156CE Service Manual online
16
KX-TDA0156CE
D) Test Command "RFPI write (RFW)"
1. Click [ Command menu ] button.
2. Point [ RF ].
3. Click [ RFPI write (RFW) ].
4. Set ID (5 byte) to the first parameter
5. Click [ Send ] button.
2. Point [ RF ].
3. Click [ RFPI write (RFW) ].
4. Set ID (5 byte) to the first parameter
5. Click [ Send ] button.
(if returned value is "OK", It succeeded. )
E) Test Command "RFPI read (RFR)"
E) Test Command "RFPI read (RFR)"
1. Click [ Command menu ] button.
2. Point [ RF ].
3. Click [ RFPI read (RFR) ].
4. Click [ Send ] button.
2. Point [ RF ].
3. Click [ RFPI read (RFR) ].
4. Click [ Send ] button.
(Returned value is ID. )
F) Test Command "software version (VER)"
F) Test Command "software version (VER)"
1. Click [ Command menu ] button.
2. Point [ others ].
3. Click [ software version (VER) ].
4. Click [ Send ] button.
2. Point [ others ].
3. Click [ software version (VER) ].
4. Click [ Send ] button.
(Returned value is software Version. )
G) Test Command "get RSSI low (RSL)"
G) Test Command "get RSSI low (RSL)"
1. Click [ Command menu ] button.
2. Point [ RF ].
3. Click [ get RSSI low (RSL) ].
4. Click [ Send ] button.
2. Point [ RF ].
3. Click [ get RSSI low (RSL) ].
4. Click [ Send ] button.
(Returned value is RSSI low value and that is written to flash ROM. )
H) Test Command "get RSSI high (RSH)"
H) Test Command "get RSSI high (RSH)"
1. Click [ Command menu ] button.
2. Point [ RF ].
3. Click [ get RSSI high (RSH) ].
4. Click [ Send ] button.
2. Point [ RF ].
3. Click [ get RSSI high (RSH) ].
4. Click [ Send ] button.
(Returned value is RSSI high value and that is written to flash ROM. )
I) Test Command "eeprom read (EPR)"
I) Test Command "eeprom read (EPR)"
1. Click [ Command menu ] button.
2. Point [ memory access ].
3. Click [ eeprom read (EPR) ].
4. Set parameters as follows.
2. Point [ memory access ].
3. Click [ eeprom read (EPR) ].
4. Set parameters as follows.
•First parameter : address No. (2 byte) : 5286
•Second parameter : Length ("1"-"10"(Hex)) : 2
•Second parameter : Length ("1"-"10"(Hex)) : 2
5. Click [ Send ] button.
(Returned value is RSSI low value and RSSI high value. )
J) Test Command "set modulaton (SMR)"
J) Test Command "set modulaton (SMR)"
1. Click [ Command menu ] button.
2. Point [ RF ].
3. Click [ set modulation (SMR) ].
2. Point [ RF ].
3. Click [ set modulation (SMR) ].
SMR XX Y
XX=Value
Y=0 for IC900
1 for IC901
XX=Value
Y=0 for IC900
1 for IC901
4. Set the value to the first parameter.
5. Click [ Send ] button.
5. Click [ Send ] button.
(if returned value is "OK", It succeeded. )
*Please adjust this value until the modulation reaches a value closest to ± 375kHz.
Click on the first or last page to see other KX-TDA0156CE service manuals if exist.