Read Panasonic KX-NTV150NE Service Manual online
14
KX-NTV150 Series
8.2.
Measure the circuit after disassembly
Before connecting to power source, measuring if VCC( VDD) to GND is short with multimeter.
Power on the unit then measuring the main voltage DC5V and DC3.3V with multimeter.
Step1
A. Turn the multimeter to resistance setting (Ω)
(with beep function).
B. Measure main board PCBA (TP14_GND) with COM probe of
(with beep function).
B. Measure main board PCBA (TP14_GND) with COM probe of
multimeter.
C. Measure main board PCBA (TP20_5V9V) with Ω probe of
multimeter, the circuit is short if there's beep sound; if not, the
circuit is normal.
circuit is normal.
Step2
A. Turn the multimeter to resistance setting (Ω)
(with beep function).
B. Measure main board PCBA (TP14_GND) with COM probe of
(with beep function).
B. Measure main board PCBA (TP14_GND) with COM probe of
multimeter.
C. Measure main board PCBA (D24_Pin1) with Ω probe of
multimeter, the circuit is short if there's beep sound; if not, the
circuit is normal.
circuit is normal.
Step1
A. Turn the multimeter to DCV setting.
B. Measure main board PCBA (TP14_GND) with COM probe of
B. Measure main board PCBA (TP14_GND) with COM probe of
multimeter.
C. Measure main board PCBA (TP20_5V9V) with Ω probe ;
check if the value is DC5.225V ~ 5.775V.
D. If the voltage is abnormal, check if other component is damage.
Step2
A. Turn the multimeter to DCV setting.
B. Measure main board PCBA (TP14_GND) with COM probe of
B. Measure main board PCBA (TP14_GND) with COM probe of
multimeter.
C. Measure main board PCBA (TP7_3V3) with Ω probe ;
check if the value is DC3.13V ~ 3.46V.
D. If the voltage is abnormal, check if other component is damage.
Click on the first or last page to see other KX-NTV150NE service manuals if exist.