KX-NT700RU - Panasonic PBX Service Manual (repair manual). Page 5

Read Panasonic KX-NT700RU Service Manual online

5
KX-NT700RU
3 Specifications
3.1.
General Descriptions
Item
Specification
Communication Mode
4 (IP, TEL, PS, PC)
IP: Communication via IP network, available in peer to peer mode and IP-
PBX mode
TEL: Communication via telephone line
PS: Communication via audio connection to a compatible Portable Station
PC: Communication via audio connection to a computer
Maximum No. of Parties
3
- Main unit user + 2 IP calls
- Main unit user + 1 IP call + 1 TEL call
- Main unit user + 1 IP call + 1 PS call
- Main unit user + 1 IP call + 1 PC call
VoIP Connection Method
SIP
VoIP Audio Codec
G.722, G.711 (
µ-law/A-law), G.729a
LAN Interface
IEEE802.3/IEEE802.3u (10/100Base-TX)
Straight/cross automatic crossover (Auto MDI/MDX)
IP Address Mode
Automatic (DHCP), manual (static)
Dial Mode
Tone, pulse
Speaker
1 (Output: 85 dB; Frequency range: 300 Hz-7000 Hz)
Built-in Microphone
4 locations, 8 total (Sensitivity area: about 3 m [about 10 ft.])
IP Network Interface Jack (LAN)
1 (RJ45)
Analog Telephone Interface Jack (LINE)
1 (RJ11)
USB Port
1 (USB 2.0, Full speed)
SD Memory Card Slot
1 (32MB - 2GB)
Audio Interface Jack (AUDIO IN/OUT)
1 (
φ 3.5 mm, monaural)
External Microphone Jack 
 (EXT MIC1,EXT MIC2)
2 (Modular jack)
Main Unit Dimensions
About 55 mm (H) 
× 275 mm (W) × 275 mm (D)
About 2 3/16 in. (H) 
× 10 1/16 in. (W) × 10 1/16 in. (D)
Main Unit Mass
About 1300 g (2.87 lb.)
AC Adaptor
Input: AC 220 V-240 V (50 Hz/60 Hz)
Output: DC 9 V 750 mA
PoE Interface
Compliant with IEEE802.3af
Power Consumption
Standby mode: about 4.8 W
Talk mode: about 6.5 W
Operating Environment
Temperature: 0 
°C-40 °C(32 °F-104 °F)
Humidity: Less than 90% (with no condensation)