KX-NT511ARUW/KX-NT511ARUB
1.2.2.  Circuit Operations
1.2.2.1.  LCD Circuit
LCD data are output from pin B9 of IC302 to LCD module.
LCD contrast is set by electronic volume(pin A13,C13).
LCD_A0
LCD_CS
LCD_D0
LCD_CLK
LCD_RST
R144
C133
C132
C131
C130
DGND
C129
CN2
1
Vss
2
ResetB
3
V0
4
V1
5
V2
6
V3
7
V4
8
Vss
9
Vdd
10 SCL
11 SI
12 CSB
13 RS
14 Vss
R145
C134
DGND
3.3V
DGND
R141
C135
DGND
R140
R143
R142
Q106
1
2
3
4
5
DGND
1
8
2
7
RA110
3
6
4
5
LCD_5V
L103
R116
5V
To LCD
IC302
R1
B9
B10
A9
C13
A13
D13
1.2.2.2.  Reset Circuit
Reset Signal is output from IC301 and input into IC302-pin L12.
C329
AGND
VDD1.2V
PWR_RST
C328
C330
L12 RSTN
M13 TEST_ANA
K12 VREF
E11 VDD0
G4 VDD1
K9 VDD2
K7 VDD3
K8 VDD4
R305
C326
C327
DGND
DGND
5V
DGND
DGND
VDD3.3V
IC301
1 VSS
2 VDD
3
CD
4
OUT
IC302