KX-NS520RU (serv.man2) - Panasonic PBX Service Manual (repair manual). Page 12

Read Panasonic KX-NS520RU (serv.man2) Service Manual online

12
KX-NS520RU
4.3.2.
Expansion Unit Mother Board
Fig.5 shows detail block diagram of Mother Board, and each function of Base is described in Table.7.
Table.7 Expansion Unit Mother Board Function Description
4.3.3.
SLIC/CODEC (SLC) Block
Refer to Service Manual of KX-NS5173/KX-NS5174.
Device/Function Block
Description
PLD1(EXT_PLD)
PLD1 controls and monitors SLIC/CODEC LSI of each analog line port.
SLIC/CODEC
SLIC/CODEC is exclusive LSI which is used for analog line interface.
    8) Line interface power supply
    9) Dial pulse detection
  10) DTMF receiver / Caller ID generation
  11) Bell signal generation
  12) Hooking detection / Ringtrip detection
  13) 2W/4W conversion
  14) CODEC function
Trunk option
Connector
Extension option
Connector
80PIN
CONN
ECT
OR
(CP
U
Int
e
rfa
ce)
RJ45
POWER I/F
Connector
Exp
a
nsi
on
 bu
s
SLIC/CODEC bus (SPI)
TDM Highway bus
AFE
SLIC/CODEC(2ch)
AFE
AFE
AFE
AFE
AFE
AFE
AFE
SLIC/CODEC(2ch)
SLIC/CODEC(2ch)
SLIC/CODEC(2ch)
SLIC/CODEC(2ch)
SLIC/CODEC(2ch)
SLIC/CODEC(2ch)
SLIC/CODEC(2ch)
ACALM, DCALM
+40V, GND
+15V, GND
RJ45
RJ45
RJ45
PLD1
(EXT_PLD)
FAN I/F
Connector
+15V, GND
INT(2)
DC/DC
+3.3 V, GND
15
12V
INT_SLIC
INT_EXT
INT_CO
FAN_ALM
RJ45
PFT
RJ45
PFT
PFT1-PFT2
PFT2-PFT3
SLT4
SLT3
Re
la
y
To SLT3-SLT4
PFT Relay
RJ45
SLT2
SLT1
Fig.5 Expansion Unit Mother Board Block Diagram
Page of 127
Display

Click on the first or last page to see other KX-NS520RU (serv.man2) service manuals if exist.