KX-NS500RU (serv.man2) - Panasonic PBX Service Manual (repair manual). Page 10

Read Panasonic KX-NS500RU (serv.man2) Service Manual online

10
KX-NS500RU
4.2.2.
Main Unit Mother Board
Fig.3 shows detail block diagram of Mother Board, and each function of Base is described in Table.5.
Table.5 Main Unit Mother Board Function Description
4.2.3.
SLIC/CODEC (SLC) Block
Refer to Service Manual of KX-NS5173/KX-NS5174.
4.2.4.
DSP (LCOT) Block
Refer to Service Manual of KX-NS5180.
4.2.5.
DPT I/F Block
Refer to Service Manual of KX-NS5170/KX-NS5171/KX-NS5172.
Device/Function Block
Description
PLD1(EXT_PLD)
PLD1 controls and monitors SLIC/CODEC LSI of each analog line port.
PLD2(CO_PLD)
PLD2 controls the trunk controller DSP which is used in each analog trunk port.
SLIC/CODEC
SLIC/CODEC is exclusive LSI which is used for analog line interface.
  1) Line interface power supply
  2) Dial pulse detection
  3) DTMF receiver / Caller ID generation
  4) Bell signal generation
  5) Hooking detection / Ringtrip detection
  6) 2W/4W conversion
  7) CODEC function
DSP(CO)
DSP(CO) is exclusive LSI which is used analog trunk port.
  1) Dial pulse generation
  2) DTMF signal generation / Caller ID detection
  3) Bell signal detection
  4) CPC signal detection
  5) 2W/4W conversion
  6) CODEC function
DPT I/F
DPT I/F is Digital Line Interface.
6
Trunk option
Connector
Extension option
Connector
80
P
IN
C
O
N
NE
C
T
O
R
(C
PU
In
te
rfa
ce)
RJ45
MOH
PAG
RJ45
RJ45
POWER I/F
Connector
Exp
ansi
on
 bu
s
SLIC/CODEC bus (SPI)
TDM Highway bus
AFE
DSP
(2ch)
AFE
AFE
SLIC/CODEC(2ch)
AFE
AFE
AFE
AFE
AFE
AFE
AFE
SLIC/CODEC(2ch)
SLIC/CODEC(2ch)
SLIC/CODEC(2ch)
SLIC/CODEC(2ch)
SLIC/CODEC(2ch)
SLIC/CODEC(2ch)
SLIC/CODEC(2ch)
DPT
I/F
(2ch)
DSP
(2ch)
ACALM, DCALM
+40V, GND
+15V, GND
Dial Pulse, CPC DET
Dial Pulse, CPC DET
RJ45
RJ45
RJ45
IIO bus
PLD1
( EXT_PLD)
DSP
(2ch)
AFE
Dial Pulse, CPC DET
DPT- I/F
FAN I/F
Connector
VBAT
+15V, GND
PLD2
(CO_PLD)
INT(2)
DC/DC
+3.3V, GND
15
12V
INT_SLIC
INT_DSP
INT
INT_EXT
INT_CO
FAN_ALM
RJ45
MOH
PAG
RJ45
MOH
PAG
CO1-CO2
CO2-CO3
CO4-CO5
Re
la
y
RJ45
SLT2
SLT1
Fig.3 Main Unit Mother Board Block Diagram
Page of 127
Display

Click on the first or last page to see other KX-NS500RU (serv.man2) service manuals if exist.