KX-NS1000UC - Panasonic PBX Service Manual (repair manual). Page 6

Read Panasonic KX-NS1000UC Service Manual online

6
KX-NS1000UC
3 Specifications
3.1.
General Description
*1 The WAN Port is not used with PCMPR Software Version 001.1.0000.
3.2.
Characterstics
Main CPU
650MHz Dual Core
Power Input
100 V AC to 130 V AC: 0.95 A/200 V AC to 240 V AC: 0.6 A;50 Hz/60 Hz
Power Consumption (when fully mounted)
50 W
(240 V: 132 VA, 200 V: 120 VA, 130 V: 104 VA, 100 V: 95 VA)
External Backup Battery
External battery port is not supported.
Support UPS: USB2.0: 1 port (Connector: Type A)
Memory Backup Duration
7 years
Dialling  
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling with Caller ID (FSK/DTMF)
1600 
Ω  Maximum
Extension 
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling with Caller ID (FSK/DTMF)
SLC1 port supports PFT in combination with the LCOT1 port connected to an analogue 
trunk.
Mode Conversion 
DP-DTMF, DTMF-DP
Ring Frequency 
20 Hz/25 Hz (selectable)
Operating
Environment
Temperature
 0 
°C to 40 °C
Humidity
10%to 90% (non-condensing)
Conference Call Trunk 
From 24 x 3-party conference call to 9 x 8-party conference call
Music on Hold (MOH)
1 ports (Level Control: -31.5 dB to +31.5 dB per 0.5 dB)
MOH1: Selectable Internal/External Music Source port
External Paging
1 port (Volume Control: -15.5 dB to +15.5 dB per 0.5 dB)
Serial Interface Port
RS-232C 
1 (maximum 115.2 kbps)
RJ45 Port
MNT Port
1 (for PC connection) 10BASE-T/100BASE-TX/1000BASE-T
(Auto MDI/MDI-X)
LAN Port
1 (for LAN connection)
WAN Port *1
1 (for WAN connection)
Extension Connection Cable
SLT
1-pair wire (T, R)
Air-cooling method
FAN
Dimension
430 mm (W) x 88 mm (H) x 340 mm (D)
Weight (when fully mounted)
Under 5.1 kg 
Terminal Equipment Loop Limit
• SLT: 600 
Ω including set
• Doorphone: 20 
Minimum Leakage Resistance
15 000 
Ω maximum
Maximum Number of Extension
Instruments per Line
1 for SLT
Ring Voltage
75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
Trunk Loop Limit
1600 
Ω maximum
Hookswitch Flash/Recall Timing Range
24 ms to 2032 ms
Door Opener Current Limit
24 V DC/30 V AC, 1 A maximum
External Sensor Current Limit
Power  to the external sensor is provided from the DOORPHONE card and must be
grounded through the DOORPHONE card. 
The PBX detects input from the sensor when the signal is under 100 
Ω.
Paging Terminal Impedance
600 
MOH (Music on Hold) Terminal Impedance
10 000 
Page of 127
Display