Read Panasonic KX-NS0290CE Service Manual online
40
KX-NS0290CE
59
CARD_SEL5
←
Card SELECT BIT [5]
60
GND
—
Power Input (GND)
61
GND
—
Power Input (GND)
62
CARD_OE
→
OUTPUT Enable Signal
63
CARD_SEL10
←
Card SELECT BIT [10]
64
CARD_SEL9
←
Card SELECT BIT [9]
65
CARD_SEL8
←
Card SELECT BIT [8]
66
CARD_SEL7
←
Card SELECT BIT [7]
67
CARD_SEL6
←
Card SELECT BIT [6]
68
GND
—
Power Input (GND)
69
GPIO5
← →
RESERVED
70
GPIO4
← →
RESERVED
71
GPIO3
← →
RESERVED
72
GPIO2
← →
RESERVED
73
GPIO1
← →
LED(SERR) CONTROL SIGNAL
74
GPIO0
← →
LOOP-BACK RELAY CONTROL SIGNAL
75
GND
—
Power Input (GND)
76
D15
← →
OPEN
77
D14
← →
OPEN
78
D13
← →
OPEN
79
D12
← →
OPEN
80
GND
—
Power Input (GND)
81
D11
← →
OPEN
82
D10
← →
OPEN
83
D9
← →
OPEN
84
D8
← →
OPEN
85
GND
—
Power Input (GND)
86
GND
—
Power Input (GND)
87
A14
→
OPEN
88
A13
→
OPEN
89
A12
→
OPEN
90
GND
—
Power Input (GND)
91
A11
→
OPEN
92
A10
→
OPEN
93
A9
→
OPEN
94
A8
→
OPEN
95
GND
—
Power Input (GND)
96
/RESET3
→
OPEN
97
/RESET2
→
OPEN
98
/RESET1
→
Software RESET signal for PRI IC
99
/RESET0
→
Software RESET signal for SLIC
100
/CS
→
Chip select signal for PRI IC
101
L_NETREF
←
Line extraction clock
102
GND
—
Power Input (GND)
103
DIN_LCOT
→
OPEN
104
DCLK_LCOT
→
OPEN
105
CP4
→
OPEN
106
GND
—
Power Input (GND)
107
CP3
→
OPEN
108
CP2
→
OPEN
109
CP1
→
Flame Header signal for PRI
110
FH/CP0
→
Flame Header signal for SLIC
111
PCLK_RESERVE
→
112
PCLK
→
113
GND
—
Power Input (GND)
114
DIN_SLC
→
Serial I/F for SLIC (DIN)
115
DCLK_SLC
→
Serial I/F for SLIC (DCLK)
116
GND
—
Power Input (GND)
117
GND
—
Power Input (GND)
118
OPEN
—
OPEN
119
15V
—
Power Input (+15V)
120
15V
—
Power Input (+15V)
No.
Signal
Direction
MAIN PRI
Function
Click on the first or last page to see other KX-NS0290CE service manuals if exist.