Read Panasonic KX-NCP1000RU Service Manual online
6
KX-NCP1000RU
3 Specifications
3.1.
General Description
3.2.
Characteristics
Control Bus
Original bus (16 bit, 8 MHz,10 megabytes per second)
Communication Bus
H.100 bus conformity (1024 time slot)
Switching
Non Blocking
Power Input
100 V AC to 130 V AC; 1.3 A/200 V AC to 240 V AC; 0.8 A; 50 Hz/60 Hz
Power Consumption (when fully mounted)
65W (240V:142VA,200V:134VA,130V:119VA,100V:113VA)
Maximum Power Failure Tolerance
300 ms
Memory Backup Duration
7 years
Dialling
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Tone (DTMF) Dialling
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Tone (DTMF) Dialling
Mode Conversion
DP-DTMF, DTMF-DP
Ring Frequency
20 Hz/25 Hz (selectable)
Trunk Loop Limit
1600
Ω maximum
Operating Environment
Temperature
0
°C to 40 °C
Humidity
10%to 90%
Conference Call Trunk
From 10 x 3-party conference call to 4 x 8-party conference call
Music on Hold (MOH)
1 port (Level Control: -6 dB to +6 dB per 3 dB)
MOH1: Selectable Internal/External Music Source port
MOH1: Selectable Internal/External Music Source port
Paging
Internal
Level Control: -6dB to +3dB per 3dB
External
1 port (Volume Control: -15 dB to +6 dB per 3dB)
Serial Interface Port
RS-232C
1 (maximum 115.2 kbps)
RJ45 Port
MNT Port
1 (for PC connection)
LAN Port
1 (for LAN connection)
Extension Connection Cable
SLT
1 pair wire (T, R)
DPT
1-pair wire (D1, D2) or
2-pair wire (T, R, D1, D2)
2-pair wire (T, R, D1, D2)
APT
2-pair wire (T, R, D1, D2)
PT-interface CS
1-pair wire (D1, D2)
PT-interface CS (High-density)
4-pair wire (D1, D2)
DSS Consoles and Add-on Key Module
1-pair wire (D1, D2)
Dimension
430 mm (W) x 130 mm (H) x 340 mm (D)
(17 in x 5 1/8 in x 13 3/8 in)
(17 in x 5 1/8 in x 13 3/8 in)
Weight (when fully mounted)
Under 8 kg (17.6 lb.)
Terminal Equipment Loop Limit
• PT: KX-DT300/KX-T7600 series DPT: 90
Ω; all other DPTs/APTs: 40Ω
• SLT: 600
Ω including set
• Doorphone: 20
Ω
• CS: 65
Ω
Minimum Leakage Resistance
15000
Ω maximum
Maximum Number of Extension
Instruments per Line
Instruments per Line
1 for PT or SLT
2 by Parallel or eXtra Device Port connection of an APT/DPT and an SLT
3 by Digital eXtra Device Port connection of 2 DPTs and an SLT
2 by Parallel or eXtra Device Port connection of an APT/DPT and an SLT
3 by Digital eXtra Device Port connection of 2 DPTs and an SLT
Ring Voltage
75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
Trunk Loop Limit
1600
Ω maximum
Hookswitch Flash/Recall Timing Range
24 ms to 2032 ms
BRI Cards Internal ISDN Mode
Supply Voltage: 40 V
Power Supply (BRI2): 4.5 W per 1 line, 9 W per 2 lines
Power Supply Method: Phantom Power Supply
Power Supply (BRI2): 4.5 W per 1 line, 9 W per 2 lines
Power Supply Method: Phantom Power Supply
Door Opener Current Limit
24 V DC/30 V AC, 1 A maximum
External Relay Current Limit
24 V DC/30 V AC, 1 A maximum
External Sensor Current Limit
Power to the external sensor is provided from the EIO4 card and must be grounded through
the EIO4 card. For the connection diagram, refer to EIO4 Card (KX-TDA0164). The PBX
detects input from the sensor when the signal is under 100
the EIO4 card. For the connection diagram, refer to EIO4 Card (KX-TDA0164). The PBX
detects input from the sensor when the signal is under 100
Ω.
Paging Terminal Impedance
600
Ω
MOH (Music on Hold) Terminal Impedance
10000
Ω
Click on the first or last page to see other KX-NCP1000RU service manuals if exist.