GP-VD100, GP-VD100E, GP-VD100CH - Panasonic PBX Service Manual (repair manual). Page 11

Read Panasonic GP-VD100 / GP-VD100E / GP-VD100CH Service Manual online

11 
GENERAL GUIDELINES
1.  When  servicing,  observe  the  original  lead  dress.  If  a 
short  circuit  is  found,  replace  all  parts  which  have  been 
over-heated or damaged by the short circuit.
2.  After  servicing,  see  to  it  that  all  the  protective  devices 
such as insulation barriers, insulation papers shields are 
properly installed.
3.  After  servicing,  make  the  following  leakage  current 
checks  to  prevent  the  customer  from  being  exposed  to 
shock hazards.
LEAKAGE CURRENT COLD CHECK
1.  Unplug  the  AC  cord  and  connect  a  jumper  between  the 
two prongs on the plug.
2.  Measure  the  resistance  value,  with  an  ohm  me-
ter,  between  the  jumpered  AC  plug  and  each  ex-
posed  metallic  cabinet  part  on  the  equipment  such 
as  screwheads,  connectors,  control  shafts,  etc. The 
resistance value must be more than 5MW.
Figure1
LEAKAGE CURRENT HOT CHECK (See Figure 1)
1.  Plug the AC cord directly into the AC outlet.
 
Do not use an isolation transformer for this check.
2.  Connect a 1.5KW, 10W resistor, in parallel with a 0.15m F 
capacitor, between each exposed metallic part on the set 
an a good earth ground such as a water pipe, as shown 
in Figure1.
3.  Use  an  AC  voltmeter,  with  1000  ohms/volt  or  more 
sensitivity, to measure the potential across the resistor.
4.  Check  each  exposed  metallic  part,  and  measure  the 
voltage at each point.
5.  Reverse the AC plug in the AC outlet repeat each of the 
above measurements.
6.  The  potential  at  any  point  should  not  exceed  0.15 
volts  RMS.  A  leakage  current  tester  (Simpson  Model 
229  equivalent)  may  be  used  to  make  the  hot  checks, 
leakage  current  must  not  exceed  0.1  milliamp.  In  case  a 
measurement is outside of the limits speci-ed,  there is a 
possibility  of  a  shock  hazard,  and  the  equipment  should 
be  repaired  and  rechecked  before  it  is  returned  to  the 
customer.
ABOUT LEAD FREE SOLDER (PbF)
Distinction of Pbf PCB:
PCBs (manufactured) using lead free solder will have a PbF 
stamp on the PCB.
Caution:
1.  Pb free solder has a higher melting point than standard  
 
solder; Typically the melting point is 50–70°F (30-40°C)
 higher.  Please  use  a  high  temperature  soldering  iron. 
In  case  of  the  soldering  iron  with  temperature  control, 
please set it to 700±20°F (370±10°C).
2.  Pb  free  solder  will  tend  to  splash  when  heated  too  high 
(about 1100°F/600°C).
ELECTROSTATICALLY SENSITIVE (ES) DEVICES
Some  semiconductor  (solid  state)  devices  can  be  damaged 
easily  by  static  electricity.  Such  components  commonly  are 
called  Electrostatically  sensitive  (ED)  Devices.  Examples 
of  typical  ES  devices  are  integrated  circuits  and  some  
-eld-eff ect transistors and semiconductor “chip” components.
The following techniques should be used to help reduce the 
incidence of component damage caused by static electricity.
1.  Immediately  before  handling  any  semiconductor 
component  or  semiconductor-equipped  assembly,  drain 
off  any  electrostatic  charge  on  your  body  by  touching  a 
known earth ground.
 
Alternatively,  obtain  and  wear  a  commercially  available 
discharging  wrist  trap  device,  which  should  be  removed 
for potential shock reasons prior to applying power to the 
unit under test.
2.  After  removing  an  electrical  assembly  equipped  with  ES 
devices,  place  the  assembly  on  a  conductive  surface 
such as alminum foil, to prevent electrostatic charge build-
up or exposure of the assembly.
3.  Use  only  a  grounded  tip  soldering  iron  to  solder  or 
unsolder ES devices.
4.  Use  only  an  anti-static  solder  removal  device  classified 
as “anti-static”  can  generate  electrical  charges  suf- cient 
to damage ES devices.
5.  Do  not  use  freon-propelled  chemicals. These  can 
generate  electrical  charges  sufficient  to  damage  ES 
devices.
6.  Do  not  remove  a  replacement  ES  device  from  its 
protective  package  until  immediately  before  you  are 
ready to install it.
 
(most  replacement  ES  devices  are  package  with  leads 
electrically  shor ted  together  by  conductive  foam, 
alminum foil or comparable conductive material).
7.  Immediately  before  removing  the  protective  material 
from  the  leads  of  a  replacement  ES  device,  touch  the 
protective material to the chassis or circuit assembly into 
which the device will be installed.
 
CAUTION : Be sure no power is applied to the chassis or 
circuit, and observe all other safety precautions.
8.  Minimize  bodily  motions  when  handling  unpackaged 
replacement  ES  devices.  (Otherwise  hamless  motion 
such  as  the  brushing  together  of  your  clothes  fabric  or 
the lifting of your foot from a carpeted  oor  can generate 
static electricity suf-cient to damage an ES de vice).
X-RADIATION
WARNING
1.  The  potential  source  of  X-radiation  in  EVF  sets  is  the 
High Voltage section and the picture tube.
2.  When  using  a  picture  tube  test  jig  for  service,  ensure 
that  jig  is  capable  of  handling  10kV  without  causing 
X-Radiation.
Note :  It  is  impor tant  to  use  an  accurate  periodically 
calibrated high voltage meter.
3.  Measure  the  High Voltage. The  meter  (electric  type) 
reading  should  indicate  2.5kV,±0.15kV.  If  the  me-
ter  indication  is  out  of  tolerance,  immediate  service 
and  correction  is  required  to  prevent  the  possibility  of 
premature  component  failure. To  prevent  an  X-Radiation 
possibility, it is essential to use the speci-ed picture tube .
  SAFETY PRECAUTIONS
AC VOLT METER
Hot-Check Circuit
COLD
WATER PIPE
(EARTH GROUND)
0.15µF
1500 OHM 10W
TO
APPLIANCE
,
S
EXPOSED
METAL PARTS
Page of 83
Display