4.4.2.3.
Concerning the Screws and Bolts Used
• When obtaining anchors and bolts locally, be absolutely sure that they satisfy the required specifications.
• Use the values recommended by the manufacturer of the anchors used for the depth to which 
the anchors are to be embedded in the wall.
• Use M6 bolts when the anchors have internal screw threads.
• Ensure that the M6 bolt has a mated length of 9 mm (0.36 in.) or longer. (See figure below.)
• Ensure that the M6 bolts do not strike the bottoms of the anchors, and check that they have been tightened up securely.
• Recommended tightening torque: 5.2 N m (53 kgf cm)