6.3. Retard Roller Mechanism
Fig. 6-3
The Retard Roller is supported by the Retard Plate. The Retard Plate is supported so that it can oscillate around the Retard Drive
Shaft at the center, and as the Retard Plate is pulled in arrow direction by the counterspring (tension coil spring), a rotation moment
in arrow direction (
) is generated with the Retard Support Shaft at the center, and an upward pressure is generated by contact
with the Separation Roller. The Pressure Adjustment Plate is supported so that it can oscillate around the Retard Support Shaft at
the center, and composition is so that the Retard Plate is pushed down by the Adjustment Cam via the Pressure Adjustment Spring
(Compression Coil Spring). The Adjustment Cam turns the cam by turning the adjustment knob 120° left and right by means of a
cylindrical cam eccentric in regard to a shaft arranged in parallel to the Retard Drive Shaft, the Pressure Adjustment Plate is pushed
down, the tension force of the counterspring is balanced corresponding to the compression force of the Adjustment Spring, and the
upward pressure of the Retard Roller is adjusted. The possible movement angle of the adjustment knob is 180°, and when it is
turned in counterclockwise direction, the push pressure is varied for the first 120°, while the pressure adjustment plate is pushed
down by the Release Cam during the last 60° to separate the Retard Roller from the Separation Roller.
The release cam pushes the Retard Plate down for separation.