KV-S3065CL, KV-S3065CW (serv.man2) - Panasonic Other Service Manuals Service Manual Supplement (repair manual). Page 10

Read Panasonic KV-S3065CL / KV-S3065CW (serv.man2) Service Manual Supplement online

10
4.3.
“Section 9.3 Operation”
This section describes each operation (or status indication), according to the function item list shown in Sec.9.2.
4.3.1.
“Section 9.3.1 Scanner Status”
This function indicates scanner status, updating it every few seconds.
The status messages and its contents are as follows.
Fig. 9.3.1 Scanner Status
Classified 
Code
Status Message
Contents
Scanner has no error.
No error
U11, U12,
U13, U14,
U15, U16,
U17
A paper jam has occurred.
Open the scanner’s door, remove the
documents, and close the cover. Place the
documents back in the document feed tray.
U11: Paper feed Jam
U12: Conveyor jam1 (Paper did not reach the Starting Sensor)
U13:Conveyor jam2 (Paper did not reach the Paper Jam Sensor) 
U14: Conveyor jam3 (Paper did not reach the Ending (Front) Sensor.)
U15: Conveyor jam 4 (Paper did not reach the Ending (Rear) Sensor.)
U16: Exit jam 1 (Paper did not go out of the Ending (Front) Sensor
         throughout)
U17: Exit Jam2 (Paper did not go out of the Ending (Rear) Sensor
         throughout)
U18
Paper remains in the scanner.
Open the scanner’s door, remove the
documents, and close the cover. Place the
documents back in the document feed tray.
Document remains in the scanner, or dust is attached around a sensor.
U20
A skew error has occurred.
Open the scanner’s door, remove the
documents, and close the cover. Place the
documents back in the document feed tray.
Skew error
U23
A paper double feed has occurred.
Open the scanner’s door, remove the
documents, and close the cover. Place the
documents back in the document feed tray.
Double feed error
U30
Scanner Door is open!
Please close the door. 
Front Door is open.
U32
Scanner Door is open!
Please close the door.
Post-imprinter Door is open.
U34
Scanner Door is open!
Please close the door.
Pre-imprinter Door is open.
Fxx
System error occurred!
Please consult with a service representative.
Service-person call level error occurred.
*** Warning***
The rollers need to be cleaned.
Please clean the rollers. Please select Clear Counter
button after cleaning rollers.
Warning for cleaning rollers.
***Warning***
The replaceable rollers (consumable) are
close to reaching their usable life.
To insure reliable operation, please replace
these rollers with Roller Exchange Kit for your
specific scanner. After replacing the rollers,
select the “Clear Counter” button.
Warning for replacing rollers.
***Warning***
Insufficient front light error occurred. The lamp
and/or scanning sensor need to be replaced.
1. The lamp have reached its life expectancy.
2. Lamp drive circuit for the front does not work properly.
***Warning***
Insufficient back light error occurred. The lamp
and/or scanning sensor need to be replaced.
1. The lamp have reached its life expectancy.
2. Lamp drive circuit for the back does not work properly.
***Warning***
The scanner’s image sensor cover is dirty and
requires routine cleaning. To insure reliable
scanning quality, open the scanner’s door
and carefully clean the scanner’s image
sensor cover.  
The surface of Image Sensor Cover is dirty.
Scanner is not connected!
Scanner is not connected to PC properly.