Read Panasonic KV-S1045C Service Manual online
33
Reassembling Note:
(1) Align the Scanning Glass (F) to the left-end of the
chassis frame until the glass goes in the direction of
the arrow (1), as seen from the front.
(2) While facing the glass in the direction of the arrow (2)
to determine the default position, insert the 4
notches to the frame of the chassis in the direction of
the arrow (3).
(3) Slide the Scanning Glass (F) in the direction of
the arrow (4), while pushing both ends of the glass, to
lock the glass.
Click on the first or last page to see other KV-S1045C service manuals if exist.