5.  OPERATIONS OF ELECTROMAGNETIC VALVES AND AIR BAGS 
Air massage operates with one Pump unit, nine 3-way electromagnetic valves, an Switch electromagnetic valve. 
1.  Air massage operates with the Pump and the Electromagnetic valve. 
2.  The Pump and all the Electromagnetic valves are OFF when the operation stops. 
3.  Air control stops when the Reclining lift motor and the Ottoman lift motor operate.(Electromagnetic valves are OFF in 
ventilation.) 
4.  The Pump stops when in the On/off operation, or Electric reclining lift unit or Electric Ottoman lift unit operate in the standby 
mode.(Pressure level is maintained.) 
Electricity is OFF in five seconds after the Packaging mode, or the operation stop after the stop mode (Packaging mode), or 
Electric reclining lift or Electric Ottoman lift are OFF in the standby
 mode. 
*However, the Lift motors operate controlling the air when in stretching of legs and ankles. 
 