EP30002KU892, EP30002CW890, EP30002KX890 - Panasonic Other Service Manuals Service Manual (repair manual). Page 9

Read Panasonic EP30002KU892 / EP30002CW890 / EP30002KX890 Service Manual online

EP30002 
ORDER NO.HPD0704X10C8
 
-
 9 - 
4.  ADJUSTMENT OF PRESSURE SENSOR 
 
The adjustment of the Pressure sensor is necessary every time after the Main PCB or Massage mechanism block are 
replaced or repaired disassembled & reassembled. 
First, keep the Massage mechanism block unloaded without pressure and move it upward halfway. 
- If the Massage mechanism block is at the highest or lowest position, you cannot arrange the pressure sensor correctly 
because the fabric becomes tense with pressure. 
 
1.  Insert the Power plug into the power source and turn on the switch of the Power source switch block. 
2.  While pushing the buttons of  Ⅰ and  Ⅲ, continue to push the On/off button for more than approximately three seconds.   
Then, the buttons of  Ⅰ,  Ⅲ, and USER A light. 
3.  In ten seconds after the buttons of Ⅰ,  Ⅲ, and USER A light, push the buttons as follows: ①SELF PROGRAM⇒②
LEG/FOOT⇒③AUTO WIDTH⇒④START 
4.  Push the button of START again, then the adjustment of Pressure sensor finishes. 
5.  Push the button of Stop. 
 
 
Page of 71
Display