Read Panasonic EP30002KU892 / EP30002CW890 / EP30002KX890 Service Manual online
EP30002
ORDER NO.HPD0704X10C8
-
54 -
13.2. CHECKING THE AIR BAGS
1. You can check the air leakage by this inspection.
Remove the Under covers.
Connect the Air inspection tool (WEP000S8908) and the
Special hose (WEP000K8917) to each Hoses from the Under
box. *Connect to the Hose that you inspect.
2. Turn the power switch on and push the On/off button on
the Controller. Open the left cover and check each
operations of LEG/FOOT, SEAT, HAND/ARM, and
SHOULDER.
3. Push the button of Air intensity on the Controller and check
the 5-level pressures. If the values are within the
standard, the Air bags, Pump unit, and Air hoses are normal. If not, the following malfunctions are assumed:
1.Bent hoses between Air bags and Pump unit
2.Malfunction of each Electromagnetic valves
3.Malfunction of Pump unit
4.Air bag rupture
Click on the first or last page to see other EP30002KU892 / EP30002CW890 / EP30002KX890 service manuals if exist.