16 -
Caution when handling the Massage mechanism block
Be sure to handle the Massage mechanism block carefully so that the
PCB of the Pressure sensor is not pushed to the desk or given extra
pressure when putting the Massage mechanism block, which could lead
to the cracks of the PCB. This may eventually cause the malfunction
such as ‘The body pressure levels on the Controller does not increase.’
‘It does not scan.’or ‘The operation is not stable.’ etc.
10.3. Removing the Controller stand and the Armrest
10.3.1. Removing the Controller
1. Pull off the parts A with a slotted screwdriver.
2. Take off the Controller from the Controller stand, and unscrew
three hexagonal screws and remove the Controller stand.
10.3.2. Removing the Armrest
1. Unscrew two screws from inside and outside the Armrest.